HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: [hylafax-users] strange situation receiving faxes



Wolfgang,

Thank you for this. Unfortunately, the chipset used is not familiar to me at all.

The modem purports "Class 1.0" but does not appear to support V.34-Fax while supporting +FAR=1, which is like Conexant, but other responses are not like any Conexant chipset I've seen. The modem purports "Class 2.1" but does not support V.34-Fax (which seems an intrinsic property of ITU T.32 Amendment 1)... and that's not like Agere/LSI chipsets that *do* support Class 2.1.

I suppose that it could be an Analog Devices or an SILabs chipset... but we don't have any well-proven prototype in HylaFAX for those chipsets.

We do have an Elsa MicroLink 56k basic prototype for Class 2.0 (config/elsa-microlink-56k-basic-2.0). That should work for you. However, for Class 1.0 you'd need to start from scratch and make adjustments based on performance.

Thanks,

Lee.


longbow wrote:
hi lee!

thx for your really fast reply!

here is the output of probemodem:

area52 ~ # probemodem
Serial port that modem is connected to []? ttyS0

Now we are going to probe the tty port.  This takes a few seconds,
so be patient.  Note that if you do not have the modem cabled to
the port, or the modem is turned off, this may hang (just go and
cable up the modem or turn it on, or whatever).

Probing for best speed to talk to modem: 38400 OK.

This looks like a Class 1, 2, 2.0, 1.0 and 2.1 modem.

ATI0 RESULT = "OK" RESPONSE = "282"
ATI1 RESULT = "OK" RESPONSE = "050"
ATI2 RESULT = "OK" RESPONSE = "OK"
ATI3 RESULT = "OK" RESPONSE = "Version 1.04 / 10.05.1999"
ATI4 RESULT = "OK" RESPONSE = " E1 L2 M0 Q0 V1 X3"
ATI5 RESULT = "OK" RESPONSE = "OK"
ATI6 RESULT = "OK" RESPONSE = "MicroLink 56k basic"
ATI7 RESULT = "OK" RESPONSE = "OK"
ATI8 RESULT = "OK" RESPONSE = "OK"
ATI9 RESULT = "OK" RESPONSE = "(#ELS075409954\MODEM\MicroLink 56k basic00)"


Class 1 stuff...

AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,1.0,2,2.0,2.1,8,8.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAE=? RESULT = "OK" RESPONSE = "0,1"
AT+FAE? RESULT = "OK" RESPONSE = "0"
AT+FTH=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FRH=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FTM=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FTS=? RESULT = "OK" RESPONSE = "0-255"
AT+FRS=? RESULT = "OK" RESPONSE = "0-255"


Class 2 stuff...

AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,1.0,2,2.0,2.1,8,8.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=2 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAXERR=? RESULT = "OK" RESPONSE = "(0-255)"
AT+FAXERR? RESULT = "OK" RESPONSE = "0"
AT+FBADLIN=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADLIN? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADMUL=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADMUL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBOR=? RESULT = "OK" RESPONSE = "(0-3)"
AT+FBOR? RESULT = "OK" RESPONSE = "0"
AT+FBUF=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBUF? RESULT = "OK" RESPONSE = "3072,400,960,0"
AT+FBUG=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FBUG? RESULT = "OK" RESPONSE = "0"
AT+FCIG=? RESULT = "OK" RESPONSE = ""(32-126)""
AT+FCIG? RESULT = "OK" RESPONSE = """"
AT+FCQ=? RESULT = "OK" RESPONSE = "(0-2),(0-2)"
AT+FCQ? RESULT = "OK" RESPONSE = "2,2"
AT+FCR=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FCR? RESULT = "OK" RESPONSE = "1"
AT+FTBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDCC=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7)"
AT+FDCC? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0"
AT+FDCS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7)"
AT+FDCS? RESULT = "OK" RESPONSE = "0,0,0,0,0,0,0,0"
AT+FDIS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7)"
AT+FDIS? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0"
AT+FDT=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDT? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FECM=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FECM? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FET=? RESULT = "OK" RESPONSE = "0-2,4-6"
AT+FET? RESULT = "OK" RESPONSE = "0"
AT+FLID=? RESULT = "OK" RESPONSE = ""(32-126)""
AT+FLID? RESULT = "OK" RESPONSE = ""AREA52 ""
AT+FLNFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLNFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLPL=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FLPL? RESULT = "OK" RESPONSE = "0"
AT+FMDL? RESULT = "OK" RESPONSE = ""MicroLink 56k basic""
AT+FMFR? RESULT = "OK" RESPONSE = ""ELSA AG, Aachen (Germany)""
AT+FMINSP=? RESULT = "OK" RESPONSE = "(0-5)"
AT+FMINSP? RESULT = "OK" RESPONSE = "0"
AT+FPHCTO=? RESULT = "OK" RESPONSE = "(0-255)"
AT+FPHCTO? RESULT = "OK" RESPONSE = "50"
AT+FPTS=? RESULT = "OK" RESPONSE = "(1-5)"
AT+FPTS? RESULT = "OK" RESPONSE = "1"
AT+FRBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FREL=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FREL? RESULT = "OK" RESPONSE = "0"
AT+FREV? RESULT = "OK" RESPONSE = ""Version 1.04 / 10.05.1999""
AT+FSPL=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FSPL? RESULT = "OK" RESPONSE = "0"
AT+FTBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FVRFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FVRFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FWDFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FWDFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FK=? RESULT = "ERROR" RESPONSE = "ERROR"


Class 2.0 stuff...

AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,1.0,2,2.0,2.1,8,8.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "2.0"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=2.0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "2.0"
AT+FJU=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJU? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDT=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FIP=? RESULT = "OK" RESPONSE = "(0)"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAP=? RESULT = "OK" RESPONSE = "(0,1),(0,1),(0,1)"
AT+FAP? RESULT = "OK" RESPONSE = "0,0,0"
AT+FBS? RESULT = "OK" RESPONSE = "C0,C0"
AT+FBO=? RESULT = "OK" RESPONSE = "(0-3)"
AT+FBO? RESULT = "OK" RESPONSE = "0"
AT+FBU=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FBU? RESULT = "OK" RESPONSE = "0"
AT+FCC=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FCC? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0,0"
AT+FCQ=? RESULT = "OK" RESPONSE = "(0-2),(0-2)"
AT+FCQ? RESULT = "OK" RESPONSE = "2,2"
AT+FCR=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FCR? RESULT = "OK" RESPONSE = "1"
AT+FCS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FCS? RESULT = "OK" RESPONSE = "0,0,0,0,0,0,0,0,0"
AT+FCT=? RESULT = "OK" RESPONSE = "(0-FF)"
AT+FCT? RESULT = "OK" RESPONSE = "30"
AT+FEA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FEA? RESULT = "OK" RESPONSE = "0"
AT+FFC=? RESULT = "OK" RESPONSE = "(0),(0),(0),(0)"
AT+FFC? RESULT = "OK" RESPONSE = "0,0,0,0"
AT+FFD=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FFD? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FHS? RESULT = "OK" RESPONSE = "0"
AT+FIE=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FIE? RESULT = "OK" RESPONSE = "0"
AT+FIS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FIS? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0,0"
AT+FIT=? RESULT = "OK" RESPONSE = "0-255,0,1"
AT+FIT? RESULT = "OK" RESPONSE = "0,0"
AT+FLI=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FLI? RESULT = "OK" RESPONSE = ""AREA52 ""
AT+FLO=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FLO? RESULT = "OK" RESPONSE = "2"
AT+FLP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FLP? RESULT = "OK" RESPONSE = "0"
AT+FMI? RESULT = "OK" RESPONSE = ""ELSA AG, Aachen (Germany)""
AT+FMM? RESULT = "OK" RESPONSE = ""MicroLink 56k basic""
AT+FMR? RESULT = "OK" RESPONSE = ""Version 1.04 / 10.05.1999""
AT+FMS=? RESULT = "OK" RESPONSE = "(0-5)"
AT+FMS? RESULT = "OK" RESPONSE = "0"
AT+FNR=? RESULT = "OK" RESPONSE = "(0,1),(0,1),(0,1),(0,1)"
AT+FNR? RESULT = "OK" RESPONSE = "1,1,1,1"
AT+FNS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FNS? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPA=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPA? RESULT = "OK" RESPONSE = """"
AT+FPI=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPI? RESULT = "OK" RESPONSE = """"
AT+FPP=? RESULT = "OK" RESPONSE = "(0)"
AT+FPP? RESULT = "OK" RESPONSE = "0"
AT+FPR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPS=? RESULT = "OK" RESPONSE = "(1-5)"
AT+FPS? RESULT = "OK" RESPONSE = "1"
AT+FPW=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPW? RESULT = "OK" RESPONSE = """"
AT+FRQ=? RESULT = "OK" RESPONSE = "(0-64),(0-FF)"
AT+FRQ? RESULT = "OK" RESPONSE = "5F,A"
AT+FRY=? RESULT = "OK" RESPONSE = "(0)"
AT+FRY? RESULT = "OK" RESPONSE = "0"
AT+FSA=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FSA? RESULT = "OK" RESPONSE = """"
AT+FSP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FSP? RESULT = "OK" RESPONSE = "0"
AT+IFC=? RESULT = "OK" RESPONSE = "+IFC: (0-3),(0-2)"
AT+IFC? RESULT = "OK" RESPONSE = "+IFC: 2,2"
AT+IPR=? RESULT = "OK" RESPONSE = "OK"
AT+IPR? RESULT = "OK" RESPONSE = "+IPR: 0"
AT+FKS=? RESULT = "ERROR" RESPONSE = "ERROR"


Class 1.0 stuff...

AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,1.0,2,2.0,2.1,8,8.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1.0"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1.0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1.0"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAE=? RESULT = "OK" RESPONSE = "0,1"
AT+FAE? RESULT = "OK" RESPONSE = "0"
AT+FTH=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FRH=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FTM=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE = "3,24,48,72-74,96-98,121,122,145,146"
AT+FTS=? RESULT = "OK" RESPONSE = "0-255"
AT+FRS=? RESULT = "OK" RESPONSE = "0-255"
AT+FAR=? RESULT = "OK" RESPONSE = "0,1"
AT+FCL=? RESULT = "OK" RESPONSE = "0-255"
AT+FIT=? RESULT = "OK" RESPONSE = "0-255,0,1"
AT+F34=? RESULT = "ERROR" RESPONSE = "ERROR"


Class 2.1 stuff...

AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,1.0,2,2.0,2.1,8,8.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "2.1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=2.1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "2.1"
AT+FJU=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJU? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDT=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FIP=? RESULT = "OK" RESPONSE = "(0)"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAP=? RESULT = "OK" RESPONSE = "(0,1),(0,1),(0,1)"
AT+FAP? RESULT = "OK" RESPONSE = "0,0,0"
AT+FBS? RESULT = "OK" RESPONSE = "C0,C0"
AT+FBO=? RESULT = "OK" RESPONSE = "(0-3)"
AT+FBO? RESULT = "OK" RESPONSE = "0"
AT+FBU=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FBU? RESULT = "OK" RESPONSE = "0"
AT+FCC=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FCC? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0,0"
AT+FCQ=? RESULT = "OK" RESPONSE = "(0-2),(0-2)"
AT+FCQ? RESULT = "OK" RESPONSE = "2,2"
AT+FCR=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FCR? RESULT = "OK" RESPONSE = "1"
AT+FCS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FCS? RESULT = "OK" RESPONSE = "0,0,0,0,0,0,0,0,0"
AT+FCT=? RESULT = "OK" RESPONSE = "(0-FF)"
AT+FCT? RESULT = "OK" RESPONSE = "30"
AT+FEA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FEA? RESULT = "OK" RESPONSE = "0"
AT+FFC=? RESULT = "OK" RESPONSE = "(0),(0),(0),(0)"
AT+FFC? RESULT = "OK" RESPONSE = "0,0,0,0"
AT+FFD=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FFD? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FHS? RESULT = "OK" RESPONSE = "0"
AT+FIE=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FIE? RESULT = "OK" RESPONSE = "0"
AT+FIS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7),(0)"
AT+FIS? RESULT = "OK" RESPONSE = "1,5,2,2,0,0,0,0,0"
AT+FIT=? RESULT = "OK" RESPONSE = "0-255,0,1"
AT+FIT? RESULT = "OK" RESPONSE = "0,0"
AT+FLI=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FLI? RESULT = "OK" RESPONSE = ""AREA52 ""
AT+FLO=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FLO? RESULT = "OK" RESPONSE = "2"
AT+FLP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FLP? RESULT = "OK" RESPONSE = "0"
AT+FMI? RESULT = "OK" RESPONSE = ""ELSA AG, Aachen (Germany)""
AT+FMM? RESULT = "OK" RESPONSE = ""MicroLink 56k basic""
AT+FMR? RESULT = "OK" RESPONSE = ""Version 1.04 / 10.05.1999""
AT+FMS=? RESULT = "OK" RESPONSE = "(0-5)"
AT+FMS? RESULT = "OK" RESPONSE = "0"
AT+FNR=? RESULT = "OK" RESPONSE = "(0,1),(0,1),(0,1),(0,1)"
AT+FNR? RESULT = "OK" RESPONSE = "1,1,1,1"
AT+FNS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FNS? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPA=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPA? RESULT = "OK" RESPONSE = """"
AT+FPI=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPI? RESULT = "OK" RESPONSE = """"
AT+FPP=? RESULT = "OK" RESPONSE = "(0)"
AT+FPP? RESULT = "OK" RESPONSE = "0"
AT+FPR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPS=? RESULT = "OK" RESPONSE = "(1-5)"
AT+FPS? RESULT = "OK" RESPONSE = "1"
AT+FPW=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FPW? RESULT = "OK" RESPONSE = """"
AT+FRQ=? RESULT = "OK" RESPONSE = "(0-64),(0-FF)"
AT+FRQ? RESULT = "OK" RESPONSE = "5F,A"
AT+FRY=? RESULT = "OK" RESPONSE = "(0)"
AT+FRY? RESULT = "OK" RESPONSE = "0"
AT+FSA=? RESULT = "OK" RESPONSE = ""(20-7E)""
AT+FSA? RESULT = "OK" RESPONSE = """"
AT+FSP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FSP? RESULT = "OK" RESPONSE = "0"
AT+IFC=? RESULT = "OK" RESPONSE = "+IFC: (0-3),(0-2)"
AT+IFC? RESULT = "OK" RESPONSE = "+IFC: 2,2"
AT+IPR=? RESULT = "OK" RESPONSE = "OK"
AT+IPR? RESULT = "OK" RESPONSE = "+IPR: 0"
AT+FKS=? RESULT = "ERROR" RESPONSE = "ERROR"



i hope you can help me with this!


thx in advance
wolfgang




Lee Howard wrote:
longbow wrote:
i now use a elsa microlink 56k basic modem - can i use the default class1 config? i know that faxaddmodem offers me a class1 setup - should i use these defaults or do i have to modify these settings?

Can you provide me the output of probemodem run against your Elsa modem? That will allow me to answer your questions.


Thanks,

Lee.



____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*





____________________ HylaFAX(tm) Users Mailing List _______________________
 To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
 *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*




Project hosted by iFAX Solutions