[hylafax-devel] Re: Modem Reset Commands
Robert Colquhoun <rjc@trump.net.au> writes:
> > > Dmitry's Proposal(i think):
> > > Config parameter default
> > > ===================================
> > > <Drop DTR>
> > > <pause>
> > > <Raise DTR>
> > > <set baud rate>
> > > ModemSoftResetCmd ATZ\n
> > > ModemResetCmds ""
> > > ModemEchoOffCmd ATE0
> > > ModemVerboseResultsCmd ATV1
> > > ...
> >
> >Yes (sorry for some delay). What's wrong with it?
>
> The problem is that the modems are all configured to perform an implicit
> ATZ on dropping/raising DTR. In that case the second explicit ATZ
> command just resets the modem to exactly the same stored values.
Explicit ATZ is not redundant: it usually resets the modem's data pump. And
it makes clear for the admin that's going on. I don't think we should save
some milliseconds here.
Hope to hear from you soon,
Dmitry