Q.
Unrecognized Transparent data command (code 44)?

I have a new USR Courier. Flexfax works fine with the Courier as a Class1 modem, but with Class2.0 I get this error:

The modem is configured for hardware flow control. The transcript is attached. Feb 03 13:24:20.21: [17852]: <-- [6:AT+FDT] Feb 03 13:24:20.39: [17852]: --> [20:+FCS:0,5,0,2,0,0,0,5] Feb 03 13:24:27.01: [17852]: --> [7:CONNECT] Feb 03 13:24:27.02: [17852]: SEND begin page Feb 03 13:24:30.07: [17852]: SENT 14196 bytes of data Feb 03 13:24:30.07: [17852]: SEND 1D RTC Feb 03 13:24:30.34: [17852]: SEND end page Feb 03 13:24:30.35: [17852]: SEND send EOP (no more pages or documents) Feb 03 13:24:30.45: [17852]: --> [2:] Feb 03 13:24:30.46: [17852]: --> [7:+FHS:44] Feb 03 13:24:30.46: [17852]: REMOTE HANGUP: Unrecognized Transparent data comma-d (code 44)

A.
This is caused by improper DTE-DCE flow control. The modem failed to see the Return To Control (RTC) command from the host and/or the <DLE><ETX> message the punctuates the end of the page data to be sent. You either have flow control misconfigured or the modem does not properly support hardware flow control in Class 2.0.


 Back to FAQ Index FAQ Index  Next question in List Q411: Unspecified Transmit Phase C error (code 40)?