Re: [hylafax-users] another issue with EICON PRI/T1



Thanks! That worked! 

This list is the absolute best, and do appreciate the help I have received.

Shawn Faulkingham


On Fri, Oct 10, 2008 at 8:13 AM, Darren Nickerson <darren@xxxxxxxxx> wrote:
Make sure to set:

Class2UseHex:           yes

-Darren


On Oct 10, 2008, at 7:54 AM, Shawn Faulkingham wrote:

I have another issue with the modems on my Eicon PRI board. If I do class 1, the modems work fine. If I try to do class2, as outlined on dialogics site, I get the following errors:

Error parsing AT+FDCC=? response: "(0-7),(0-D),(0-2),(0-2),0,(0-2),0,0"
/dev/ttyds01: Can not initialize modem


I have looked everywhere for a solution, but to no avail. Any help is appreciated, and thanks to all for the help earlier.

Regards,

Shawn Faulkingham