Hello, It seems that one of our clients has particular facsimile or settings for their fax server. Every time someone from my company sending a fax to this number get "No carrier detected". My fax card is MainPine QUATRO+. gru 06 19:03:31.41: [25399]: SESSION BEGIN 000024990 XXXX gru 06 19:03:31.41: [25399]: HylaFAX (tm) Version 4.3.4 gru 06 19:03:31.41: [25399]: SEND FAX: JOB 19776 DEST XXXX COMMID 000024990 DEVICE '/dev/ttyS5' FROM 'user <user@mach1>' USER user gru 06 19:03:31.41: [25399]: STATE CHANGE: RUNNING -> SENDING gru 06 19:03:31.41: [25399]: Apply DialString rules to "YYYY" gru 06 19:03:31.41: [25399]: --> return result "YYYY" gru 06 19:03:31.41: [25399]: <-- [14:AT+FCLASS=1.0\r] gru 06 19:03:31.42: [25399]: --> [2:OK] gru 06 19:03:31.42: [25399]: DIAL YYYY gru 06 19:03:31.42: [25399]: <-- [16:ATDTYYYY\r] gru 06 19:03:41.21: [25399]: --> [2:OK] gru 06 19:03:41.21: [25399]: SEND FAILED: JOB 19776 DEST 00225215619 ERR No carrier detected gru 06 19:03:41.21: [25399]: <-- [5:ATH0\r] gru 06 19:03:41.26: [25399]: --> [2:OK] gru 06 19:03:41.26: [25399]: MODEM set DTR OFF gru 06 19:03:41.26: [25399]: STATE CHANGE: SENDING -> MODEMWAIT (timeout 5) gru 06 19:03:41.26: [25399]: SESSION END I tried to change ModemWaitTimeCmd as I read that it helps with such strange exceptions but no luck. Here is my config for this modem # CountryCode: 00 AreaCode: 00 FAXNumber: +XXXX LongDistancePrefix: 00 InternationalPrefix: 00 DialStringRules: etc/dialrules ServerTracing: 0xFFFFF SessionTracing: 0xFFFFF RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 1 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "+XXXX" TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c|Page %%P of %%T" MaxRecvPages: 25 # ModemType: Class1.0 # use this to supply a hint ModemRate: 57600 # must be at least as fast as the DCE-DCE communication ModemFlowControl: rtscts # many firmwares have broken software flow control Class1EnableV34Cmd: AT+F34=14,1,2 # 33600-2400 primary, 2400-1200 control Class1TMConnectDelay: 400 # counteract quick CONNECT response CallIDPattern: "NMBR=" CallIDPattern: "NAME=" ModemWaitTimeCmd ATS7=100 Can anyone please point me out what can I do with this strange behaviour? Regards, Marcin ____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*