I am have been running hylafax for years now on my Mandrake Linux 10.1
system. It has 3 - MultiTech (LT V.92 1.0 MT5634ZPX-PCI-U Internal
Data/Fax/Voice Modem Version 1.32i) modems. We use them for receiving
only and they are configured for class 1.0.
The problem it that occasionally we recieve faxes that give "MODEM No
carrier" messages. The messages seem to originate from the same fax
machines and those fax machines return "Poor Line Quality" messages.
May 01 11:06:00.51: [ 2851]: SESSION BEGIN 000029658 18017059051
May 01 11:06:00.51: [ 2851]: HylaFAX (tm) Version 4.3.3
May 01 11:06:00.51: [ 2851]: <-- [4:ATA\r]
May 01 11:06:11.27: [ 2851]: --> [7:CONNECT]
May 01 11:06:11.27: [ 2851]: ANSWER: FAX CONNECTION DEVICE '/dev/ttyS5'
May 01 11:06:11.27: [ 2851]: RECV FAX: begin
May 01 11:06:11.27: [ 2851]: <-- data [32]
May 01 11:06:11.27: [ 2851]: <-- data [2]
May 01 11:06:11.28: [ 2851]: --> [7:CONNECT]
May 01 11:06:11.28: [ 2851]: <-- data [23]
May 01 11:06:11.28: [ 2851]: <-- data [2]
May 01 11:06:11.28: [ 2851]: --> [7:CONNECT]
May 01 11:06:11.28: [ 2851]: <-- data [13]
May 01 11:06:11.28: [ 2851]: <-- data [2]
May 01 11:06:13.58: [ 2851]: --> [2:OK]
May 01 11:06:13.58: [ 2851]: <-- [9:AT+FRH=3\r]
May 01 11:06:15.43: [ 2851]: --> [7:CONNECT]
May 01 11:06:17.35: [ 2851]: --> [10:NO CARRIER]
May 01 11:06:17.35: [ 2851]: MODEM No carrier
May 01 11:06:17.35: [ 2851]: <-- [9:AT+FRS=7\r]
May 01 11:06:17.43: [ 2851]: --> [2:OK]
May 01 11:06:17.43: [ 2851]: <-- [9:AT+FTH=3\r]
May 01 11:06:18.38: [ 2851]: --> [7:CONNECT]
May 01 11:06:18.39: [ 2851]: <-- data [3]
May 01 11:06:18.39: [ 2851]: <-- data [2]
May 01 11:06:18.77: [ 2851]: --> [2:OK]
May 01 11:06:18.77: [ 2851]: RECV send CRP (command repeat)
May 01 11:06:18.77: [ 2851]: <-- [9:AT+FRH=3\r]
May 01 11:06:21.21: [ 2851]: --> [7:CONNECT]
May 01 11:06:22.37: [ 2851]: --> [2:OK]
May 01 11:06:22.37: [ 2851]: RECV FAX: RSPREC error/got DCN
May 01 11:06:22.37: [ 2851]: RECV FAX: end
May 01 11:06:22.37: [ 2851]: SESSION END
------------------------------------------------------------------------
# $Id: lucent-mt-10,v 1.8 2005/12/05 15:48:54 darren Exp $
#
# prototype config for MultiTech 5634-series modems using
# the Lucent/Agere chipset supporting V.34-Fax.
#
#
CountryCode: 1
AreaCode: 801
FAXNumber: +1.801.705.9051
LongDistancePrefix: 1
InternationalPrefix: 011
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 1
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 0
SpeakerVolume: quiet
GettyArgs: ""
LocalIdentifier: "MJN Services, Inc."
#
ModemType: Class1.0 # use this to supply a hint
ModemRate: 57600 # must be at least as fast as
the DCE-DCE communication
ModemFlowControl: rtscts # many firmwares have broken
software flow control
Class1EnableV34Cmd: AT+F34=14,1,2 # 33600-2400 primary,
2400-1200 control
Class1TMConnectDelay: 400 # counteract quick CONNECT
response
Class1ECMSupport: Yes
Class1PersistentECM: Yes
Class1ECMFrameSize: 64
#
# Older firmwares on MainPine cards may require this:
# Class1Cmd: AT+FCLASS=1
#
# If your line supports Caller-ID, you may want to uncomment this...
# ModemResetCmds: AT+VCID=1
# CallIDPattern: "NMBR="
# CallIDPattern: "NAME="
# Or with the MT5634ZBA-DID you'll probably need something like...
# ModemReadyCmds: AT*DS1*DD0*DF1*DN4 # enable DTMF-DID,
wink-start, 4 digits
# CallIDPattern: "DTMF" # format of AT*DF1
# CallIDAnswerLength: 4 # four DTMF-DID digits then ATA