HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
Re: [hylafax-users] 3com u.s. robotics 5
Hello
Unfortunately I have no experience of using USR modems in Class 2.0.
Others on the list will be much more competent than I to take it from
here. Only suggestion I have is try using Class 1 - I do recall someone
here saying that the USRs are problematic in Class 2.0
In case it helps here is my config for a similar modem 245630-02
=============================================
FAXNumber: +44.01remainder concealed
LongDistancePrefix: ""
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 3
RecvFileMode: 0644
LogFileMode: 0644
DeviceMode: 0600
RingsBeforeAnswer: 3
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "BSW Timber (Group HQ - Earlston)"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: " From %%l|%c|Page %%P of %%T"
MaxRecvPages: 25
CIDNumber: "NMBR = "
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
# Temporary addition of ATS6=4 (delay b4 dialling) for BCM autodial of 9
ModemResetCmds: AT#CID=1S6=4
ModemType: Class1 # use class 1 interface
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: RTSCTS
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow
control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow
control
ModemResultCodesCmd: ATQ0X4 # enable result codes
#
ModemMfrQueryCmd: !USR
ModemModelQueryCmd: ATI3
ModemRevQueryCmd: ATI7 # XXX returns a multi-line result
#
# When AT+FCLASS=1 is issued the modem automatically switches
# to software flow control; these parameters let the fax software
# reset flow control as needed after entering Class 1.
#
Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no flow control
Class1HFLOCmd: AT&H1&I0&R2 # setup modem for hardware flow
control
Class1SFLOCmd: "" # modem does this automatically
#
# This should resolve "DIS/DTC received 3 times" errors:
#
Class1ResponseWaitCmd: AT+FRS=1 # wait after sending TCF for
response
#
# The remainder of this configuration is included so that the
# modem "idles" in Class 0 while not sending or receiving facsimile.
#
ModemSetupAACmd: AT+FCLASS=0 # leave modem idling in class 0
ModemAnswerCmd: AT+FCLASS=1A # answer in Class 1
#
# Disables the reporting of bad frames by the modem. This
# overcomes a firmware problem in the x2 and V90 Sportsters.
# It is not necessary for the Courier modem.
#
Class2NRCmd: AT+FNR=1,1,1,0
# Below at Lee Howard's suggestion, to overcome USR 5630 resets during
MCF
Class1SwitchingCmd: "<delay:7>" # silence between HDLC recv and
trans
======================================
Regards
Bill A.
-----Original Message-----
From: mauro.sanna@xxxxxxxxxxxxxxxxxx
Sent: 14 November 2006 12:29
To: Bill Allison
Cc: hylafax-users@xxxxxxxxxxx
Subject: Re: [hylafax-users] 3com u.s. robotics 5
--------------------------------------------------------------------------
--
> I can probably help if your problem is with the settings for this
modem,
> but your session log indicates there is something wrong with the number
> given to hylafax to dial, and others on the list will be more able than
I
> to suggest where that's gone wrong (with the client?)
>
> Where your log shows "DIAL ??? # number" I would have expected it to
say
> "DIAL 8441" as per the 3rd line of your log. I suspect the problem is
> with the client or how you are using it. How are you sending the fax -
> using sendfax within a script or using a client of some sort? If the
> former let us see the script. Might be useful to post doneq/q11.
Here is the complete session log:
nov 14 13:20:25.86: [ 4356]: SESSION BEGIN 000000066 00390708441
nov 14 13:20:25.86: [ 4356]: HylaFAX (tm) Version 4.2.1
nov 14 13:20:25.86: [ 4356]: SEND FAX: JOB 14 DEST 8441 COMMID 000000066
DEVICE
'/dev/ttyS0'
nov 14 13:20:25.86: [ 4356]: <-- [9:AT+FLO=2\r]
nov 14 13:20:26.11: [ 4356]: --> [2:OK]
nov 14 13:20:26.11: [ 4356]: <-- [9:AT+FPP=0\r]
nov 14 13:20:26.36: [ 4356]: --> [2:OK]
nov 14 13:20:26.36: [ 4356]: <-- [9:AT+FBO=0\r]
nov 14 13:20:26.61: [ 4356]: --> [2:OK]
nov 14 13:20:26.61: [ 4356]: <-- [10:AT+FCT=30\r]
nov 14 13:20:26.86: [ 4356]: --> [2:OK]
nov 14 13:20:26.86: [ 4356]: <-- [15:AT+FNR=1,1,1,0\r]
nov 14 13:20:27.11: [ 4356]: --> [2:OK]
nov 14 13:20:27.11: [ 4356]: <-- [9:AT+FIE=0\r]
nov 14 13:20:27.36: [ 4356]: --> [2:OK]
nov 14 13:20:27.36: [ 4356]: <-- [23:AT+FCC=1,5,2,2,0,0,0,0\r]
nov 14 13:20:27.62: [ 4356]: --> [2:OK]
nov 14 13:20:27.62: [ 4356]: DIAL 8441
nov 14 13:20:27.62: [ 4356]: <-- [9:ATDT8441\r]
nov 14 13:20:42.71: [ 4356]: --> [4:+FCO]
nov 14 13:20:46.00: [ 4356]: --> [27:+FCI:" 0706778441"]
nov 14 13:20:46.00: [ 4356]: REMOTE CSI "0706778441"
nov 14 13:20:46.00: [ 4356]: --> [20:+FIS:1,5,0,2,1,0,0,3]
nov 14 13:20:46.00: [ 4356]: --> [2:OK]
nov 14 13:20:46.00: [ 4356]: REMOTE best rate 14400 bit/s
nov 14 13:20:46.00: [ 4356]: REMOTE max A4 page width (215 mm)
nov 14 13:20:46.00: [ 4356]: REMOTE max unlimited page length
nov 14 13:20:46.00: [ 4356]: REMOTE best vres 7.7 line/mm
nov 14 13:20:46.00: [ 4356]: REMOTE best format 2-D MR
nov 14 13:20:46.00: [ 4356]: REMOTE best 10 ms/scanline
nov 14 13:20:46.00: [ 4356]: USE 14400 bit/s
nov 14 13:20:46.00: [ 4356]: USE 10 ms/scanline
nov 14 13:20:46.00: [ 4356]: <-- [5:ATH0\r]
nov 14 13:20:46.25: [ 4356]: --> [2:OK]
nov 14 13:20:46.25: [ 4356]: SESSION END
it says:
FaxQueuer[4330]: NOTIFY: bin/notify "doneq/q14" "failed" "0:36"
Nov 14 13:20:46 fax1 FaxQueuer[4330]: NOTIFY exit status: 0 (4358)
I can't get where is the problem.
With another modem I can send faxes without any problem.
With this Robotic is a problem.
Here is my configuration:
ModemType: Class2.0 # use class 2.0 interface
ModemRate: 9600 # DCE-DTE communication rate
ModemFlowControl: rtscts # hardware flow control
#
ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow
control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow
control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
ModemResultCodesCmd: ATQ0X4 # enable extended result codes
#
ModemSetupAACmd: AT+FAA=1
ModemSetVolumeCmd: "ATM0 ATM1 ATM1 ATM1 ATM1"
#
Class2BUGCmd: AT+FBU=0
#
#
Class2CQQueryCmd: !(0),(0) # override modem response
#
#
Class2NRCmd: AT+FNR=1,1,1,0
Class2SendRTC: yes
#
Class2APQueryCmd: none
____________________ HylaFAX(tm) Users Mailing List
_______________________
To subscribe/unsubscribe, click
http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx <
/dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*
--
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*