OK Ill dig up some log files during the day. I don't suppose there's any way to switch from class 2 to class 1 on the fly is there? -----Original Message----- From: Lee Howard [mailto:faxguy@xxxxxxxxxxxxxxxx] Sent: Tuesday, February 21, 2006 7:18 AM To: Declan Shanaghy Cc: hylafax-users@xxxxxxxxxxx Subject: Re: [hylafax-users] high %age of international faxes fail Declan Shanaghy wrote: >Its probably overkill to send complete error logs. > > Perhaps, but just sending me the error message does not help, either. >The usual errors fall in a wide range > >Invalid response to MPS >DCS sent 3 times without response >No carrier detected >COMREC error in transmit >COMREC invalid command response >Failure to train at 2400 >Unspecified Transmit Phase B/C >No response to EOP repeat > >I have even seen "No carrier detected" and used a regular >fax machine with no problems afterwards. > > Some of these look like Class 2 errors... are you running in Class 2 or Class 1? If you're running in Class 2 switching to Class 1 should help. Lee. ____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx* ____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*