HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
[hylafax-users] Send but no recieve
Hello
I used a USR Sportster Voice 33.6 Fax Modem, I can send Fax but Can't
receive... On a mandrake 10.1, the modem is on the serial port 2 (ttyS1),
hylafax 4.2,
I dont forget to do #faxgetty ttyS1
My config.ttyS1 file is :
CountryCode: 33
AreaCode: 3
FAXNumber: +33.03.xxxxxxxx
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: quiet
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "NothingSetup"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%P of %%T"
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use class 1 interface
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: xonxoff # software flow control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow control
ModemResultCodesCmd: ATQ0X4 # enable result codes
#
ModemMfrQueryCmd: !USR
ModemModelQueryCmd: ATI3
ModemRevQueryCmd: ATI7 # XXX returns a multi-line result
#
# When AT+FCLASS=1 is issued the modem automatically switches
# to software flow control; these parameters let the fax software
# reset flow control as needed after entering Class 1.
#
Class1NFLOCmd: AT&H0&I0&R1 # setup modem for no flow control
Class1HFLOCmd: AT&H1&I0&R2 # setup modem for hardware flow control
Class1SFLOCmd: "" # modem does this automatically
#
# This should resolve "DIS/DTC received 3 times" errors:
#
Class1ResponseWaitCmd: AT+FRS=1 # wait after sending TCF for response
#
# The remainder of this configuration is included so that the
# modem "idles" in Class 0 while not sending or receiving facsimile.
#
ModemSetupAACmd: AT+FCLASS=0 # leave modem idling in class 0
ModemAnswerCmd: AT+FCLASS=1A # answer in Class 1
#
# Disables the reporting of bad frames by the modem. This
# overcomes a firmware problem in the x2 and V90 Sportsters.
# It is not necessary for the Courier modem.
#
Class2NRCmd: AT+FNR=1,1,1,0
probemodem command result is :
This looks like a Class 1 and 2.0 modem.
ATI0 RESULT = "OK" RESPONSE = "3361"
ATI1 RESULT = "OK" RESPONSE = "966D"
ATI2 RESULT = "OK" RESPONSE = "OK"
ATI3 RESULT = "OK" RESPONSE = "USRobotics Sportster Voice 33600 Fax Rev.
2.0"
ATI4 RESULT = "OK" RESPONSE = "USRobotics Sportster Voice 33600 Fax
Settings..."
ATI5 RESULT = "Strike a key when ready . . ." RESPONSE = "USRobotics
Sportster Voice 33600 Fax NVRAM Settings..."
ATI6 RESULT = "OK" RESPONSE = "USRobotics Sportster Voice 33600 Fax Link
Diagnostics..."
ATI7 RESULT = "OK" RESPONSE = "Configuration Profile..."
ATI8 RESULT = "OK" RESPONSE = "Blacklist"
ATI9 RESULT = "OK" RESPONSE = "(1.0USR0007\Modem\Sportster 33600
FAX/VOICE EXT)FF"
Class 1 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "0"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAE=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAE? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRS=? RESULT = "ERROR" RESPONSE = "ERROR"
Class 2.0 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=2.0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJU=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJU? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDR=? RESULT = "" RESPONSE = ""
AT+FDT=? RESULT = "" RESPONSE = ""
AT+FIP=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAP=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAP? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBS? RESULT = "OK" RESPONSE = "1800,4000"
AT+FBO=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FBO? RESULT = "OK" RESPONSE = "0"
AT+FBU=? RESULT = "OK" RESPONSE = "0"
AT+FBU? RESULT = "OK" RESPONSE = "0"
AT+FCC=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),0,0,0,
(0-7)"
AT+FCC? RESULT = "OK" RESPONSE = "1,5,0,2,0,0,0,5"
AT+FCQ=? RESULT = "OK" RESPONSE = "(0-2),(0-2)"
AT+FCQ? RESULT = "OK" RESPONSE = "1,0"
AT+FCR=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FCR? RESULT = "OK" RESPONSE = "1"
AT+FCS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCS? RESULT = "OK" RESPONSE = "0,0,0,0,0,0,0,0"
AT+FCT=? RESULT = "OK" RESPONSE = "(0-255)"
AT+FCT? RESULT = "OK" RESPONSE = "0"
AT+FEA=? RESULT = "OK" RESPONSE = "0"
AT+FEA? RESULT = "OK" RESPONSE = "0"
AT+FFC=? RESULT = "OK" RESPONSE = "0,0,0,0"
AT+FFC? RESULT = "OK" RESPONSE = "0,0,0,0"
AT+FFD=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FFD? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FHS? RESULT = "OK" RESPONSE = "0"
AT+FIE=? RESULT = "OK" RESPONSE = "0"
AT+FIE? RESULT = "OK" RESPONSE = "0"
AT+FIS=? RESULT = "OK" RESPONSE = "(0,1),(0-5),(0-2),(0-2),0,0,0,
(0-7)"
AT+FIS? RESULT = "OK" RESPONSE = "1,5,0,2,0,0,0,5"
AT+FIT=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FIT? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLI=? RESULT = "OK" RESPONSE = "(20-7E)"
AT+FLI? RESULT = "OK" RESPONSE = """"
AT+FLO=? RESULT = "OK" RESPONSE = "(0-2)"
AT+FLO? RESULT = "OK" RESPONSE = "1"
AT+FLP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FLP? RESULT = "OK" RESPONSE = "0"
AT+FMI? RESULT = "OK" RESPONSE = "USRobotics Sportster V.34+ FAX"
AT+FMM? RESULT = "OK" RESPONSE = "OK"
AT+FMR? RESULT = "OK" RESPONSE = "OK"
AT+FMS=? RESULT = "OK" RESPONSE = "(0-5)"
AT+FMS? RESULT = "OK" RESPONSE = "0"
AT+FNR=? RESULT = "OK" RESPONSE = "(0,1),(0,1),(0,1),(0,1)"
AT+FNR? RESULT = "OK" RESPONSE = "0,0,0,0"
AT+FNS=? RESULT = "OK" RESPONSE = "(20-7E)"
AT+FNS? RESULT = "OK" RESPONSE = """"
AT+FPA=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPA? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPI=? RESULT = "OK" RESPONSE = "(20-7E)"
AT+FPI? RESULT = "OK" RESPONSE = """"
AT+FPP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FPP? RESULT = "OK" RESPONSE = "0"
AT+FPR=? RESULT = "OK" RESPONSE = "(0,1,2,4,8,16,24)"
AT+FPR? RESULT = "OK" RESPONSE = "0"
AT+FPS=? RESULT = "OK" RESPONSE = "(1-5)"
AT+FPS? RESULT = "OK" RESPONSE = "1"
AT+FPW=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPW? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRQ=? RESULT = "OK" RESPONSE = "(0-2),(0-2)"
AT+FRQ? RESULT = "OK" RESPONSE = "0,N"
AT+FRY=? RESULT = "OK" RESPONSE = "0"
AT+FRY? RESULT = "OK" RESPONSE = "0"
AT+FSA=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FSA? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FSP=? RESULT = "OK" RESPONSE = "(0,1)"
AT+FSP? RESULT = "OK" RESPONSE = "0"
AT+IFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+IFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+IPR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+IPR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FKS=? RESULT = "ERROR" RESPONSE = "ERROR"
/var/log/messages:
Jun 1 11:50:33 amonbofis FaxGetty[8024]: MODEM USR USRobotics Sportster Voice
33600 Fax Rev. 2.0/Configuration Profile... Product type France
External Options V32bis,V.FC,V.34+ Fax Options
Class 1/Class 2.0 Clock Freq 92.0Mhz Eprom 256k
Ram 64k EPROM date 5/10/96 DSP date
5/10/96 EPROM rev 2.0 DSP rev 2.0
Jun 1 11:50:33 amonbofis FaxGetty[8024]: LOCKWAIT
Jun 1 11:50:46 amonbofis FaxSend[8678]: MODEM USR USRobotics Sportster Voice
33600 Fax Rev. 2.0/Configuration Profile... Product type France
External Options V32bis,V.FC,V.34+ Fax Options
Class 1/Class 2.0 Clock Freq 92.0Mhz Eprom 256k
Ram 64k EPROM date 5/10/96 DSP date
5/10/96 EPROM rev 2.0 DSP rev 2.0
What I do wrong ? thank for futur all
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null