HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

[hylafax-users] waiting for modem



Im using a Maestro Woomera external modem ( RC288dpi chipset) with hylafax 
and it just wont work
have tested all hardware and installs hylafax works fine with other modems 
this modem works fine with minicom also in windows with winfax but just wont 
init properly with hylafax.
keep getting waiting for modem to come ready or initializing server with 
faxstat 
below is output from probemodem and my config.ttyS1 file.


Probing for best speed to talk to modem: 38400 OK.

This looks like a Class 1+2 modem.

ATI0    RESULT = "OK"   RESPONSE = "56000"
ATI1    RESULT = "OK"   RESPONSE = "255"
ATI2    RESULT = "OK"   RESPONSE = "OK"
ATI3    RESULT = "OK"   RESPONSE = "V2.210E56 0101-V90_2M_DLS"

Class 1 stuff...

AT+FCLASS=?     RESULT = "OK"   RESPONSE = "0,1,2,1.0"
AT+FCLASS?      RESULT = "OK"   RESPONSE = "0"
AT+FCLASS=0     RESULT = "OK"   RESPONSE = "OK"
AT+FCLASS=1     RESULT = "OK"   RESPONSE = "OK"
AT+FCLASS?      RESULT = "OK"   RESPONSE = "1"
AT+FJUNK=?      RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FJUNK?       RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FAA=?        RESULT = "OK"   RESPONSE = "0,1"
AT+FAA? RESULT = "OK"   RESPONSE = "0"
AT+FAE=?        RESULT = "OK"   RESPONSE = "0,1"
AT+FAE? RESULT = "OK"   RESPONSE = "0"
AT+FTH=?        RESULT = "OK"   RESPONSE = 
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRH=?        RESULT = "OK"   RESPONSE = 
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTM=?        RESULT = "OK"   RESPONSE = 
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=?        RESULT = "OK"   RESPONSE = 
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=?        RESULT = "OK"   RESPONSE = "0-255"
AT+FRS=?        RESULT = "OK"   RESPONSE = "0-255"

Class 2 stuff...

AT+FCLASS=?     RESULT = "OK"   RESPONSE = "0,1,2,1.0"
AT+FCLASS?      RESULT = "OK"   RESPONSE = "1"
AT+FCLASS=0     RESULT = "OK"   RESPONSE = "OK"
AT+FCLASS=1     RESULT = "OK"   RESPONSE = "OK"
AT+FCLASS=2     RESULT = "OK"   RESPONSE = "OK"
AT+FCLASS?      RESULT = "OK"   RESPONSE = "2"
AT+FJUNK=?      RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FJUNK?       RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FAA=?        RESULT = "OK"   RESPONSE = "0,1"
AT+FAA? RESULT = "OK"   RESPONSE = "0"
AT+FAXERR=?     RESULT = "OK"   RESPONSE = "0-255"
AT+FAXERR?      RESULT = "OK"   RESPONSE = "0"
AT+FBADLIN=?    RESULT = "OK"   RESPONSE = "0"
AT+FBADLIN?     RESULT = "OK"   RESPONSE = "0"
AT+FBADMUL=?    RESULT = "OK"   RESPONSE = "0"
AT+FBADMUL?     RESULT = "OK"   RESPONSE = "0"
AT+FBOR=?       RESULT = "OK"   RESPONSE = "0-3"
AT+FBOR?        RESULT = "OK"   RESPONSE = "0"
AT+FBUF=?       RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FBUF?        RESULT = "OK"   RESPONSE = "16384,13107,3276,0"
AT+FBUG=?       RESULT = "OK"   RESPONSE = "0"
AT+FBUG?        RESULT = "OK"   RESPONSE = "0"
AT+FCIG=?       RESULT = "OK"   RESPONSE = "(20)(32,33,35-96,123-126)"
AT+FCIG?        RESULT = "OK"   RESPONSE = "OK"
AT+FCQ=?        RESULT = "OK"   RESPONSE = "0"
AT+FCQ? RESULT = "OK"   RESPONSE = "0"
AT+FCR=?        RESULT = "OK"   RESPONSE = "0,1"
AT+FCR? RESULT = "OK"   RESPONSE = "0"
AT+FTBC=?       RESULT = "OK"   RESPONSE = "0"
AT+FTBC?        RESULT = "OK"   RESPONSE = "0"
AT+FDCC=?       RESULT = "OK"   RESPONSE = 
"(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7)"AT+FDCC?        RESULT = "OK"   RESPONSE 
= "0,5,0,2,0,0,0,0"
AT+FDCS=?       RESULT = "OK"   RESPONSE = 
"(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7)"AT+FDCS?        RESULT = "OK"   RESPONSE 
= "0,0,0,0,0,0,0,0"
AT+FDIS=?       RESULT = "OK"   RESPONSE = 
"(0,1),(0-5),(0-2),(0-2),0,0,0,(0-7)"AT+FDIS?        RESULT = "OK"   RESPONSE 
= "0,5,0,2,0,0,0,0"
AT+FDT=?        RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FDT? RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FECM=?       RESULT = "OK"   RESPONSE = "0"
AT+FECM?        RESULT = "OK"   RESPONSE = "0"
AT+FET=?        RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FET? RESULT = "ERROR"        RESPONSE = "ERROR"
AT+FLID=?       RESULT = "OK"   RESPONSE = "(20)(32,33,35-96,123-126)"
AT+FLID?        RESULT = "OK"   RESPONSE = "OK"
AT+FLNFC=?      RESULT = "OK"   RESPONSE = "0"
AT+FLNFC?       RESULT = "OK"   RESPONSE = "0"
AT+FLPL=?       RESULT = "OK"   RESPONSE = "0,1"
AT+FLPL?        RESULT = "OK"   RESPONSE = "0"
AT+FMDL?        RESULT = "OK"   RESPONSE = "AC/K56              "
AT+FMFR?        RESULT = "OK"   RESPONSE = "ROCKWELL"
AT+FMINSP=?     RESULT = "OK"   RESPONSE = "0"
AT+FMINSP?      RESULT = "OK"   RESPONSE = "0"
AT+FPHCTO=?     RESULT = "OK"   RESPONSE = "0-255"
AT+FPHCTO?      RESULT = "OK"   RESPONSE = "30"
AT+FPTS=?       RESULT = "OK"   RESPONSE = "1-5"
AT+FPTS?        RESULT = "OK"   RESPONSE = "0"
AT+FRBC=?       RESULT = "OK"   RESPONSE = "0"
AT+FRBC?        RESULT = "OK"   RESPONSE = "0"
AT+FREL=?       RESULT = "OK"   RESPONSE = "0"
AT+FREL?        RESULT = "OK"   RESPONSE = "0"
AT+FREV?        RESULT = "OK"   RESPONSE = "V2.210E56 0101-V90_2M_DLS"
AT+FSPL=?       RESULT = "OK"   RESPONSE = "0,1"
AT+FSPL?        RESULT = "OK"   RESPONSE = "0"
AT+FTBC=?       RESULT = "OK"   RESPONSE = "0"
AT+FTBC?        RESULT = "OK"   RESPONSE = "0"
AT+FVRFC=?      RESULT = "OK"   RESPONSE = "0"
AT+FVRFC?       RESULT = "OK"   RESPONSE = "0"
AT+FWDFC=?      RESULT = "OK"   RESPONSE = "0"
AT+FWDFC?       RESULT = "OK"   RESPONSE = "0"
AT+FK=? RESULT = "ERROR"        RESPONSE = "ERROR"

# Configuration for a Rockwell RC288DPi-based Class 1 modem.
#    Hayes Optima 28800		firmware rev ???
#    Microcom DeskPorte 28.8S	firmware rev V1.100K-V34_DS
#    PPI PM288FXMT		firmware rev 1.57
#
# Note that the modem does not lock the line rate for fax
# receive (at least not the PM288FXMT); but not sure whether
# current flow control settings are maintained or if it
# switches to XON/XOFF (testing host was too fast to see).
#
#
CountryCode:		61
AreaCode:		07
FAXNumber:		38090803
LongDistancePrefix:	1
InternationalPrefix:	011
DialStringRules:	etc/dialrules
ServerTracing:		0x08501
SessionTracing:		0x08501
RecvFileMode:		0640
LogFileMode:		0640
DeviceMode:		0660
RingsBeforeAnswer:	1
SpeakerVolume:		off
GettyArgs:		"-r -b %l"
LocalIdentifier:	KenPurchaseCarriers
TagLineFormat:		"From %%l|%c|Page %%P of %%T"
MaxRecvPages:		25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class1		# use this to supply a hint
ModemRate:		38400		# rate for DCE-DTE communication
ModemFlowControl:	rtscts		# default
#
ModemNoFlowCmd:		AT&K0		# setup no flow control
ModemHardFlowCmd:	AT&K3		# setup hardware flow control
ModemSoftFlowCmd:	AT&K4		# setup software flow control
ModemSetupDTRCmd:	AT&D2		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
#
ModemMfrQueryCmd:	!Rockwell
ModemModelQueryCmd:	!RC288DPi
ModemRevQueryCmd:	ATI3		# product information
#
ModemDialCmd:		ATDT%s		# T for tone dialing

____________________ HylaFAX(tm) Users Mailing List _______________________
  To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
 On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
  *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*




Project hosted by iFAX Solutions