Re: [hylafax-users] recieve error with terboline19k2 modem
Lee Howard wrote:
On 2004.03.11 02:45 Volker Weber wrote:
i have three logs attched, the first one created a corrupt tiff (
file says: "TIFF image data, little-endian", but i cant display or
convert it ).
the second an third came from teh same sender and produced no output
(tiff file).
any hints?
Mar 11 10:43:50.54: [ 519]: RECV: 57 total lines, 53 bad lines, 34
consecutive
bad lines
Mar 11 10:48:21.69: [ 519]: RECV: 962 total lines, 620 bad lines, 109
consecutive bad lines
You may need to use:
ModemRecvFillOrder: LSB2MSB
Lee.
I have this in my config.ttyS0 file.
here is the complete content:
# $Id: skel,v 1.4 2002/04/07 20:29:27 darren Exp $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the
names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 441
FAXNumber: +49.441.6834891
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 0
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "Volker Weber"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l +49 441 6834891|%c|Page %%P of %%T"
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use this to supply a hint
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: rtscts # RTS/CTS flow control assumed
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
#
# We can append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: ATDT%s # T for tone dialing
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds: ATZ # stuff to do when modem is reset
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT&K # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH0 # place phone on hook (hangup)
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for
transmit
Class2RecvDataTrigger: "\022"
--
-------------------------------------------------------------------------
Volker Weber Dietrichsweg 38a 26127 Oldenburg Germany
MAILTO:Volker@xxxxxxxxxxxxxxxxxx HTTP://www.v-weber.de
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxxxxx*