HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: [hylafax-users] Hylafax 33.6K compatabile modem?



On 2004.02.18 12:23 Mike McMullen wrote:
Hi All,

Can anyone recommend a good cheap 33.6K modem
that works well with Hylafax?

By 33.6K I assume you mean SuperG3 or V.34-fax.


It appears you're using analog lines, thus, you're options are limited to using Class 2.1 with MultiTech MT5634ZBA-V92, MT5634ZPX-PCI-V92, or ISI5634PCI (or others in the same MultiTech model lines) modems.

Someday when HylaFAX supports Class 1.0 (which is not the same thing as Class 1) then you will probably have many more options.

If you're interested in assisting that development, see http://bugs.hylafax.org/bugzilla/show_bug.cgi?id=77 Now that HylaFAX CVS supports ECM in Class 1, all of the necessary prerequisites are in-place. It's now just down to a matter of coding it as mentioned in the bug report.

Lee.

____________________ HylaFAX(tm) Users Mailing List _______________________
 To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
 *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxxxxx*




Project hosted by iFAX Solutions