Re: [hylafax-users] flow control problems?
On 2002.07.11 09:21 Blair McKay wrote:
>
> Hi,
>
> I have installed 3 multitech MT5634ZPX-PCI-V92 Internal Data/Fax/Voice
> Modem
> Version 1.25p. After having wedging problems with USR modems.
>
> Now I seem to be having problems with what I assume to be flow control.
> Running the modems as class 2.0 resulted in multiple errors and failures,
> as
> well as producing truncated and garbled tiff output. Rendering it almost
> useless.
You're going to HAVE to use CVS with these modems in Class 2.0. They give
reporting in hex format which will break current HylaFAX code. Also,
these modems support V.34-fax (Super G3), and CVS has that enabled, too...
as well as some other dandy features.
> Will upgrading to the current version have noticable results?
> Are there modem config files containing proper strings that I am missing?
You'll need to upgrade to CVS and then re-run faxaddmodem.
If you don't want to use CVS, then you'll need to run in Class 2 or Class
1 until the next code release.
Lee.