[hylafax-users] Unspecified Receive Phase B error (code 70)
Hello,
I can send faxes without any problem. However, when trying to receive
faxes from different fax machines I get "Communication Error" in the
middle of transmission reported on the fax machine's end. In Hylafax log
I get the following:
Dec 06 16:20:21.34: [ 3280]: SESSION BEGIN 00000116 xxxxxxxx
Dec 06 16:20:21.34: [ 3280]: <-- [4:ATA\r]
Dec 06 16:20:23.50: [ 3280]: --> [3:FAX]
Dec 06 16:20:29.26: [ 3280]: --> [5:+FCON]
Dec 06 16:20:29.26: [ 3280]: ANSWER: FAX CONNECTION
Dec 06 16:20:29.26: [ 3280]: RECV FAX: begin
Dec 06 16:23:29.26: [ 3280]: REMOTE HANGUP: Unspecified Receive Phase B
error (c
ode 70)
Dec 06 16:23:29.26: [ 3280]: RECV FAX: Unspecified Receive Phase B error
Dec 06 16:23:29.26: [ 3280]: RECV FAX: end
Dec 06 16:23:29.26: [ 3280]: SESSION END
I saw several messages posted about the same problem; however, there was
no good answer to the problem. I tried different things I could think of
or find on the web. Nothing helps. Anybody knows what is wrong?
I have SoundBlaster Modem (Rockwell chipset is reported by hylafax
during installation).
I use hylafax-4.1beta2-2rh7 (obviously on RH 7).
Thank you.