HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
Re: [hylafax-users] [SOLVED] RE: factors in bad scan lines
>> in the config file. I never would have caught that on my own. So, I guess
>> that my question is, how are you supposed to know the proper settings for:
>>
>> ModemSendFillOrder
>> ModemRecvFillOrder
>> ModemFrameFillOrder
>>
>> as I've never seen them listed in any manual?
>
>What about T.30? :-)
Okay, you got me. :) I haven't read T.30.
>The correct settings are:
>
>Class1:
>ModemSendFillOrder LSB2MSB
>ModemRecvFillOrder LSB2MSB
>ModemFrameFillOrder LSB2MSB
>
>Class2:
>ModemSendFillOrder LSB2MSB
>ModemRecvFillOrder MSB2LSB (infamous Rockwell bug)
>ModemFrameFillOrder Not applicable
>
>Initially Rockwell was introduced this bug in its modem's data pump (Class2
>also assumed LSB2MSB), which most software and hardware makers had to
>follow. I know the only exception -- non-Rockwell Multitech modems, that
>implements the original Class2 specs and use LSB2MSB for ModemRecvFillOrder.
>
>Class2.0:
>ModemSendFillOrder LSB2MSB
>ModemRecvFillOrder LSB2MSB
>ModemFrameFillOrder Not applicable
Thank you!
So, should a "default" config setting for Class 2 be 'ModemRecvFillOrder:
MSB2LSB' ?
This "default" wouldn't work for Multitech, but for everything else?
Lee.
____________________ HylaFAX(tm) Users Mailing List _______________________
To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null