Lee Howard <faxguy@deanox.com> writes: > >Y'know, Lee; that log looks an awful-helluva lot like flow control. > >Especially all those incoming TSI's. > > Yes, it does. It happens whether I use xonxoff or rtscts. I haven't tried > none. How did you switched them on? Proper flow control should be set via special fax mode commands (AT+FLO for Class2.0; not specified for Class1 or Class2, so such modems use their own non-standard methods). ModemFlowControl: <something> in your config is usually *not* enough. > >The USR has some instrumentation for Line levels, though I forget > >where, and I think the Supra may have an S-register for that sort of > >thing, too; I had one to play with, but that's been 8 years back. > > I've got the AT and AT+F command set summary. I've attached the S Register > command set below. I really don't know what I'm looking for... so if > you're really *that* bored, I've attached them below. ;) S-regs for TX-level adjusting (S39 for USR) do not work for all countries and usually are undocumented. Hope to hear from you soon, Dmitry ____________________ HylaFAX(tm) Users Mailing List _______________________ To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null