> Mar 02 02:14:52.18: [13546]: RECV: send trigger 021 Hylafax sends default Class 2 receive trigger (DC1). > Mar 02 02:14:52.18: [13546]: <-- data [1] Modem returns one byte, possibly DCx > Mar 02 02:16:20.07: [13546]: <-- data [1] Modem returns one more byte after 1m 28s, much too long for a real fax; probably modem trying to abort connection. Chances are that this is one of the class 2 modems that requires receive trigger set to DC2 (\022) not DC1; see recent articles on the list. Chances are that it is really a Rockwell modem. Could also be a flow control problem, e.g. misconfigured cable. > ------=_NextPart_000_0019_01BE648B.E46C7F20 > Content-Type: text/html; > charset="iso-8859-1" > Content-Transfer-Encoding: quoted-printable Please fix your email program so it doesn't send HTML to mailing lists; even Outlook, MS-Mail and Netscape can be made to behave. > <!DOCTYPE HTML PUBLIC "-//W3C//DTD W3 HTML//EN"> The content of the HTML is incompatible with the DOCTYPE, which only permits HTML 2.0.