HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Hayes Accura 336/56K wont hang up properly?




This only happens when sending faxes, receiving happens normally. All
sessions end like this: 

Oct 18 16:23:04.34: [11279]: SENT 41354 bytes of data
Oct 18 16:23:04.34: [11279]: <-- data [2]
Oct 18 16:23:04.34: [11279]: SEND end page
Oct 18 16:23:07.17: [11279]: --> [2:OK]
Oct 18 16:23:07.17: [11279]: SEND send EOP (no more pages or documents)
Oct 18 16:23:07.17: [11279]: <-- [9:AT+FET=2\r]
Oct 18 16:23:10.58: [11279]: --> [7:+FPTS:1]
Oct 18 16:23:10.58: [11279]: SEND recv MCF (message confirmation)
Oct 18 16:23:10.58: [11279]: SEND FAX (00000910): FROM 
 roadmr@utopia.entropia.com.mx TO 14 (page 2 of 2 sent in 0:26)
Oct 18 16:23:10.58: [11279]: SEND FAX (00000910): FROM
 roadmr@utopia.entropia.com.mx TO 14 (docq/doc216.ps;01 sent in 0:26)
Oct 18 16:23:10.59: [11279]: <-- [4:ATH\r]
Oct 18 16:23:10.70: [11279]: --> [7:+FHNG:2]
Oct 18 16:23:10.70: [11279]: REMOTE HANGUP: Call aborted,  from +FK or
 <CAN> (code 2)
Oct 18 16:23:10.70: [11279]: --> [2:OK]
Oct 18 16:23:10.70: [11279]: SESSION END

Oddly this happens after Hylafax sends the ATH command to the modem; so in
theory everything has already been closed up properly. However the modem
says "FHNG:2", and so Hylafax doesn't think the session ended properly.

The server runs Red Hat Linux 5.1, and HylaFax 4.0pl1 (will upgrading to
pl2 help?). The modem, as I said, is a Hayes Accura 336/56K external. I
even tried applying the v.90 upgrade to see if it helped, but it didn't.

I'm using the "rc288dpi" modem config file, except for the <19200><xon>
answer begin command (not needed by this modem).

Does anyone know of a solution or workaround for this problem?

	- Roadmaster

----------------
*
Save a tree- use E-Mail!			roadmr@entropia.com.mx
*




Project hosted by iFAX Solutions