Re: Modem hanging - ELSA 33.6 TQV
Hi,
I solved the problem by my self - it was the flow-control. I enabled
uni-directional xon/xoff instead of bi-directional xon/xoff when in
faxmode. Here is the new working config for the ELSA 33.6 TQV
(tested for 8 days, 703 facsimile sent, 420 facsimile received, only
one error beside of busy - wrong number entered by the user. -> great)
Thanx to Andreas Haumer and Christophe Zwecker for help !
#
# Class 2.0 modem configuration for ELSA 33.6 TQV.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 481
FAXNumber: +49.481.8571.51
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0644
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "+49.481.8571-51"
LogFacility: local7
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "Von %%l|%c|Seite %%p von %%t"
PercentGoodLines: 80
MaxConsecutiveBadLines: 20
MaxRecvPages: 250
ModemPriority: 200
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2.0 # use this to supply a hint
ModemRate: 115200 # max rate for DCE-DTE
communication
ModemFlowControl: rtscts # XON/XOFF flow control assumed
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: ATDT%s
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
#ModemResetCmds: ATX3 # stuff to do when modem
is reset
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT\Q0
ModemHardFlowCmd: AT\Q3
ModemSoftFlowCmd: AT\Q1
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH # place phone on hook (hangup)
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received
facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for
transmit
#
# Configuration parameters for Class 2.0 modems.
#
Class2Cmd: AT+FCLASS=2.0 # command to enter class 2.0
Class2BORCmd: AT+FBO=0 # bit order for phase B/C/D
(direct)
Class2CQCmd: "" # commands to enable copy
quality proc.
Class2AbortCmd: AT+FKS # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality
capabilities
Class2DCCQueryCmd: AT+FCC=? # query for modem capabilities
Class2TBCCmd: AT+FPP=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FCT=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBU=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLI # set local identifier command
Class2DCCCmd: AT+FCC # set modem capabilities command
Class2DISCmd: AT+FIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command
hack
Class2CIGCmd: AT+FPI # set polling identifier command
Class2NRCmd: AT+FNR=1,1,1,1 # setup status reporting command
Class2PIECmd: AT+FIE=0 # disable interrupt-enable
command
Class2PTSCmd: AT+FPS # set post-page status command
Class2SPLCmd: AT+FSP # set polling indicator command
Class2NFLOCmd: AT+FLO=0 # set no flow control command
Class2SFLOCmd: AT+FLO=1 # set software flow control
command
Class2HFLOCmd: AT+FLO=2 # set hardware flow control
command
--
Michael Möller A. Heinemann Heide GmbH & Co.KG
Unix-Systemadministrator Technische Gebäudeausrüstung
moeller.heinemann@t-online.de Süderdamm 5, 25746 Heide, Germany
D2:0172/4576755 Fax:05334/7485 oder 0481/87654 Tel.:0481/8571-0