Philips modem
Has anybody successfully configured a Philips 28.8 modem?
The user manual identifies the modem simply as "Philips Fax modem". Faxaddmodem
used the generic class 2 configuration. In the server logs I always find these lines:
Jun 3 12:05:48 idefix2 FaxGetty[556]: --> [15:ROCKWELL 144DPI]
Jun 3 12:05:48 idefix2 FaxGetty[556]: MODEM PHILIPS ROCKWELL 144DPI/KA1131-00
When sending a fax over this modem, I always get some "MODEM command errors", and hardly any faxes really get through. Can anybody help me? Here's my config.tty1A:
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use this to supply a hint
ModemRate: 38400
ModemFlowControl: xonxoff # XON/XOFF flow control assumed
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: ATX3DT%s@ # T for tone dialing,
# @ for silence
# X3: Don't wait for dialtone
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
####
#### According to the manual, there is no AT&K_ command. So I try to use AT\Q_ instead.
####
ModemResetCmds: "" # stuff to do when modem is reset
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT\Q0 # disable flow control cmd
ModemHardFlowCmd: AT\Q3 # hardware flow control cmd
ModemSoftFlowCmd: AT\Q1 # software flow control cmd
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH0 # place phone on hook (hangup)
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd: AT+FCLASS=2 # command to enter class 2
Class2BORCmd: AT+FBOR=0 # bit order for phase B/C/D (direct)
Class2RELCmd: AT+FREL=1 # byte-align EOL codes on recv
Class2CQCmd: "" # commands to enable copy quality proc.
Class2AbortCmd: AT+FK # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality capabilities
Class2DCCQueryCmd: AT+FDCC=? # query for modem capabilities
Class2TBCCmd: AT+FTBC=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FPHCTO=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBUG=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLID # set local identifier command
Class2DCCCmd: AT+FDCC # set modem capabilities command
Class2DISCmd: AT+FDIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command hack
Class2CIGCmd: AT+FCIG # set polling identifier command
Class2PTSCmd: AT+FPTS # set post-page status command
Class2SPLCmd: AT+FSPL # set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger: "" # character sent to modem to start recv
Class2XmitWaitForXON: yes # if true, wait for XON before send
--
Alexandre Meissonnier
Dohle Handelsgruppe Systemberatung GmbH
53719 Siegburg (Germany)
ameissonnier@dohle.com