Section 3 : Running a Server

Q324: How to config ModemClass / ModemGroup?


? Got something to say about this answer? Hit the question mark to invoke the mailer and send your comments to the HylaFAQ maintainers.

Q.
Re: How do I configure ModemClass to reserve a modem for inbound use only ?

A.

Note! Note : The configuration parameter ModemClass was renamed to ModemGroup in version 4.1.

From: Phil Watkinson <pkw@elgro.co.uk>
To: HylaFAX List <hylafax-users@hylafax.org>
Cc: Ste <:rlpivk.044@tellnet.pesaro.ps.it>
Date: 08 March 1999 15:59

The ModemClass parameter does not define whether the modem is
class 1, 2, or whatever, but to define a name for a set of modems.

The correct syntax would be:

ModemClass:	"any:	ttyS[0-1]"

This would set the default fax modems to use for any job to be ttyS0
and ttyS1; leaving, say, the modem on ttyS2 to be used by HylaFAX solely
for inbound faxes.

If you have only one modem, or not interested in this advanced feature,
then delete the ModemClass parameter out of the modem config (eg config.ttyS1)
file.


Ciao
Phil Watkinson
Boston, UK.