HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

[hylafax-users] R: V.21 signal reception timeout +FCERROR



BadPageHandlingMethod is present in hylafax 6.0.5 also. Seeing man hylafax-config:

 

AnswerBias                    integer    -                bias to apply to successful rotary answer

AreaCode                     string     -                local area code

AuditHook                    string  -      command to run for faxq event auditing

BadPageHandlingMethod         string     RTN-SAVE         bad page received handling method

BatchLogs                    boolean    Yes              keep all session logs of a batch in a single log

CallIDAnswerLength            integer    -                answer call when CallIDPattern received

CallIDPattern                 strint     -                call identification pattern string

CIDName                       string     -                equivalent to CallIDPattern (2)

CIDNameAnswerLength           integer    0                equivalent to CallIDAnswerLength (2)

 