HylaFAX The world's most advanced open source fax server |
Hi,
that's it !
Thanks for help Lee.
Lars
----- Originalnachricht -----
Von: Lee Howard <faxguy@xxxxxxxxxxxxxxxx>
An: Meuser, Lars
Cc: hylafax-users@xxxxxxxxxxx <hylafax-users@xxxxxxxxxxx>
Gesendet: Sat Jun 28 22:02:56 2008
Betreff: Re: [hylafax-users] CallIDPattern
Meuser, Lars wrote:
> Hi,
> i am a little bit confused about CallIDPattern.
> Last week i asked for "who is generating CallID's".
>
> I get these information at start of an fax transmission:
> -----
> Jun 23 16:36:17.28: [ 2780]: SESSION BEGIN 000000072 +49xxxxxx340
> Jun 23 16:36:17.28: [ 2780]: HylaFAX (tm) Version 5.2.5
> Jun 23 16:36:17.28: [ 2780]: <-- [4:ATA\r]
> Jun 23 16:36:17.28: [ 2780]: --> [8:CID: 321]
> Jun 23 16:36:17.28: [ 2780]: --> [8:DAD: 340]
> Jun 23 16:36:17.28: [ 2780]: --> [4:RING]
> Jun 23 16:36:30.01: [ 2780]: --> [5:+FCON]
> Jun 23 16:36:30.01: [ 2780]: ANSWER: FAX CONNECTION DEVICE
> '/dev/ttyds01'
CID and DAD shouldn't be appearing in the session log. They need to
come before the ATA. Thus you need to increase your RingsBeforeAnswer.
Thanks,
Lee.