Talking to a number of different machines, Multitech Class 1.0 (5632 serial modem), traditional phone line, getting a number of these sorts of errors:
Mar 24 07:46:46.19: [62998]: USE 2-D MMR
Mar 24 07:47:09.54: [62998]: SEND send PPS (partial page signal) Mar 24 07:47:09.54: [62998]: SEND send MPS (more pages, same document) Mar 24 07:47:09.54: [62998]: <-- [9:AT+FRH=3\r] Mar 24 07:47:09.63: [62998]: --> [7:CONNECT] Mar 24 07:47:10.85: [62998]: --> [2:OK] Mar 24 07:47:10.85: [62998]: SEND recv DCN (disconnect) Mar 24 07:47:10.85: [62998]: <-- [9:AT+FRS=7\r] Mar 24 07:47:11.06: [62998]: --> [2:OK] Mar 24 07:47:11.06: [62998]: COMREC invalid response received to PPS.
Any ideas? Its happening to a significant number of remotes - perhaps 100 out of 500, and is pretty consistent.
I also am getting these:
Mar 25 10:23:02.78: [40101]: USE 2-D MMR
Mar 25 10:23:38.63: [40101]: No response to PPS repeated 3 times.
.... boom! looks like the other end just disappeared.