HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: [hylafax-users] Multi serial solutions



Andrew Rinaldi wrote:
choose a board that has a "PCI Status Register"...

Sorry, that should have said "PCI Interrupt Status Register". This register allows the serial driver to examine the status of all board interrupts without polling each port in tern. This register was a standard feature of the first multiport serial cards when they were launched in the 1980's and is invaluable for optimising interrupt service routine performance.


This is one reason why we can run 128 fax ports simultaneously on a 1.2GHz PIII machine.

Regards

Andrew Rinaldi
Mainpine Developer Support
USA +1 503 822 9944 | UK +44 8458 909438
andrew.rinaldi@xxxxxxxxxxxx | www.mainpine.com


____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*