Re: [hylafax-users] R: How to decrease Modem Initialization Time



Pier Paolo Proietti wrote:

I read the thread but In the hylafax website I can't find any reference to
these two strings:
Class1RMQueryCmd: !24,48,72,73,74,96,97,98,121,122,145,146
Class1TMQueryCmd: !24,48,72,73,74,96,97,98,121,122,145,146

Commands: Class1RMQueryCmd and Class1TMQueryCmd are not mentioned in the
website. Why?
Are they obsolete?


They're not obsolete. I see them here:


http://hylafax.sourceforge.net/man/hylafax-config.php

Note also that you must enclose the setting in quotes to use the "!". Thus:

Class1RMQueryCmd: "!24,48,72,73,74,96,97,98,121,122,145,146"
Class1TMQueryCmd: "!24,48,72,73,74,96,97,98,121,122,145,146"


Thanks,


Lee.


____________________ HylaFAX(tm) Users Mailing List _______________________ To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null *To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*