Re: [hylafax-users] R: How to decrease Modem Initialization Time
Pier Paolo Proietti wrote:
I read the thread but In the hylafax website I can't find any reference to
these two strings:
Class1RMQueryCmd: !24,48,72,73,74,96,97,98,121,122,145,146
Class1TMQueryCmd: !24,48,72,73,74,96,97,98,121,122,145,146
Commands: Class1RMQueryCmd and Class1TMQueryCmd are not mentioned in the
website. Why?
Are they obsolete?
They're not obsolete. I see them here:
http://hylafax.sourceforge.net/man/hylafax-config.php
Note also that you must enclose the setting in quotes to use the "!". Thus:
Class1RMQueryCmd: "!24,48,72,73,74,96,97,98,121,122,145,146"
Class1TMQueryCmd: "!24,48,72,73,74,96,97,98,121,122,145,146"
Thanks,
Lee.