HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
[hylafax-users] Updating a prototype
I'd like to update the config/conexant-1.0 prototype to have my modem
recognized.
It's an italian Digicom Leonardo 56k, here is the probemodem output.
Following faxaddmomem man page, I tried adding the "right" comment into
the prototype, but never succeeded.
I tried:
# CONFIG:CLASS1.0:Line speed.*:.*.*: Manufacturer=Digicom Model=Leonardo
and
# CONFIG:CLASS1.0:.*:.*LEONARDO.*.*: Manufacturer=Digicom Model=Leonardo
I think that a : between ATI3 and flow control is missing in conexant-1.0.
I added it but faxaddmodem still doesn't recognize the modem.
How do I merge the prototype manually?
Removing lines beginning with "modem related stuff..." at the bottom of
etc/config.ttyxx and appending lines from the prototype?
Thanks
Ciao,
Filippo
Probing for best speed to talk to modem: 38400 OK.
This looks like a Class 1, 2 and 1.0 modem.
ATI0 RESULT = "OK" RESPONSE = "Line speed: 56000"
ATI1 RESULT = "OK" RESPONSE = "Prodotto: LEONARDO 56K Digicom
S.p.A."
ATI2 RESULT = "OK" RESPONSE = "OK"
ATI3 RESULT = "OK" RESPONSE = "Prodotto: LEONARDO 56K Digicom
S.p.A."
ATI4 RESULT = "OK" RESPONSE = "Rel: V2.200-D1.5 31/08/99"
ATI5 RESULT = "OK" RESPONSE = "Country code: 008"
ATI6 RESULT = "OK" RESPONSE = "Dp type: RCV56DPF-PLL L8571A
Rev 30.00/30.00"
ATI7 RESULT = "OK" RESPONSE = "Sw ver: V2.200-V90_2M_DLS"
ATI8 RESULT = "ERROR" RESPONSE = "ERROR"
ATI9 RESULT = "ERROR" RESPONSE = "ERROR"
Class 1 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2,1.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "0,1"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAE=? RESULT = "OK" RESPONSE = "0,1"
AT+FAE? RESULT = "OK" RESPONSE = "0"
AT+FTH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=? RESULT = "OK" RESPONSE = "0-255"
AT+FRS=? RESULT = "OK" RESPONSE = "0-255"
Class 2 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2,1.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=2 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "0,1"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAXERR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAXERR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADLIN=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADLIN? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADMUL=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBADMUL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBOR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBOR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBUF=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBUF? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBUG=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FBUG? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCIG=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCIG? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCQ=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCQ? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCR=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FCR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDCC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDCC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDCS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDCS? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDIS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDIS? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDT=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FDT? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FECM=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FECM? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FET=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FET? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLID=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLID? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLNFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLNFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLPL=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FLPL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FMDL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FMFR? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FMINSP=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FMINSP? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPHCTO=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPHCTO? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPTS=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FPTS? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FRBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FREL=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FREL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FREV? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FSPL=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FSPL? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FTBC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FVRFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FVRFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FWDFC=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FWDFC? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FK=? RESULT = "ERROR" RESPONSE = "ERROR"
Class 1.0 stuff...
AT+FCLASS=? RESULT = "OK" RESPONSE = "0,1,2,1.0"
AT+FCLASS? RESULT = "OK" RESPONSE = "1.0"
AT+FCLASS=0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS=1.0 RESULT = "OK" RESPONSE = "OK"
AT+FCLASS? RESULT = "OK" RESPONSE = "1.0"
AT+FJUNK=? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FJUNK? RESULT = "ERROR" RESPONSE = "ERROR"
AT+FAA=? RESULT = "OK" RESPONSE = "0,1"
AT+FAA? RESULT = "OK" RESPONSE = "0"
AT+FAE=? RESULT = "OK" RESPONSE = "0,1"
AT+FAE? RESULT = "OK" RESPONSE = "0"
AT+FTH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRH=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FRM=? RESULT = "OK" RESPONSE =
"3,24,48,72,73,74,96,97,98,121,122,145,146"
AT+FTS=? RESULT = "OK" RESPONSE = "0-255"
AT+FRS=? RESULT = "OK" RESPONSE = "0-255"
AT+FAR=? RESULT = "OK" RESPONSE = "0,1"
AT+FCL=? RESULT = "OK" RESPONSE = "0-255"
AT+FIT=? RESULT = "OK" RESPONSE = "(0-255),(0,1)"
AT+F34=? RESULT = "ERROR" RESPONSE = "ERROR"
____________________ HylaFAX(tm) Users Mailing List _______________________
To subscribe/unsubscribe, click http://lists.hylafax.org/cgi-bin/lsg2.cgi
On UNIX: mail -s unsubscribe hylafax-users-request@xxxxxxxxxxx < /dev/null
*To learn about commercial HylaFAX(tm) support, mail sales@xxxxxxxxx*