Re: [hylafax-users] Urgent: How to get extra dialed number
Hi, Lee,
I still have problem to make it work, I already
configured config.ttyS0 as follow. But when I dial
1234567, I do not hear any sounds, then I continue
dial 1234, after a while, the fax server just hangs
up.
Any idea??
config.ttyS0:
==================================================
# The following to allow routing in FaxDispatch via
DNIS
ModemRingResponse: AT+FCLASS=8;H1
CIDNumber: SHIELDED_DTMF
CIDNumberAnswerLength: 4
ModemAnswerCmd: AT+FCLASS=1;A
#
#
# Modem-related stuff: should reflect modem command
interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use this to
supply a hint
ModemRate: 19200 # rate for
DCE-DTE communication
ModemFlowControl: rtscts # default
#
ModemNoFlowCmd: AT&K0 # setup no
flow control
ModemHardFlowCmd: AT&K3 # setup
hardware flow control
ModemSoftFlowCmd: AT&K4 # setup
software flow control
ModemSetupDTRCmd: AT&D2 # setup so DTR
drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD
reflects carrier (or not)
#
#ModemMfrQueryCmd: !Rockwell
#ModemModelQueryCmd: !RC288DPi
ModemMfrQueryCmd: ATI3
ModemModelQueryCmd: ATI0
ModemRevQueryCmd: ATI3 # product
information
#
ModemDialCmd: ATDT%s^ # T for tone
dialing
#
RecvDataFormat: adaptive # only 1-D MR
#Use2DS1 No
#
#
Class1Cmd: AT+FCLASS=1 # command to
enter class 1
Class1PPMWaitCmd: AT+FTS=7 # command to
stop and wait before PPM
Class1TCFWaitCmd: AT+FTS=7 # command to
stop and wait before TCF
Class1EOPWaitCmd: AT+FTS=9 # command to
stop and wait before EOP
Class1TCFResponseDelay: 75 # 75ms delay
between recv TCF & response
Class1SendMsgDelay: 75 # 75ms delay
after training
Class1SwitchingDelay: 75 # 150ms delay
in switching transmission direction
Class1TrainingRecovery: 1500 # 1.5sec delay
after training failure
Class1RecvAbortOK: 200 # wait 200ms
for abort response
Class1FrameOverhead: 4 # 4 byte
overhead in recvd HDLC frames
Class1RecvIdentTimer: 40000 # 35+5secs
waiting for ident frames
Class1TCFMaxNonZero: 100 # max 10% of
data may be non-zero
Class1TCFMinRun: 1000 # min run is
2/3rds of TCF duration
==================================================
Thanks in advance,
~xun
--- Lee Howard <faxguy@xxxxxxxxxxxxxxxx> wrote:
> Xun Hu wrote:
>
> >Hi, Lee,
> >
> >Thanks, and then how can I get the dialed number?
> if I
> >define
> >
> >ModemRingResponse: AT+FCLASS=8;H1
> > CIDNumber: SHIELDED_DTMF
> > CIDNumberAnswerLength: 4
> > ModemAnswerCmd: AT+FCLASS=1;A
> >
> >Let's say user dials 1234567 then dial 1234
> >
> >How can I get 1234?
> >
> >
>
> The 1234 shows up in faxrcvd/FaxDispatch (see 'man
> faxrcvd') as $CIDNUMBER.
>
> Basically what those configuration options are
> saying is for the modem
> to briefly enter voice mode and go off-hook when a
> ring is detected.
> Then it is to sit there and listen for four DTMF
> digits before it will
> then answer the call in fax mode and proceed with
> fax reception.
>
> Realize, then, that the caller will need to dial
> those four digits
> *after* the call is connected. So they would dial
> "1234567" and then
> when the call is answered (ringing stops), then dial
> "1234". Then the
> 1234 will show up in FaxDispatch as $CIDNUMBER.
>
> That said, SHIELDED_DTMF wasn't designed for this
> kind of usage
> (although there should be no problem with this kind
> of usage).
> SHEILDED_DTMF was designed for usage with PBXes that
> could signal DID
> through to analog modems in this fashion.
>
> Lee.
>
>
-------------------------------------------------------------
| http://www.4warding.com - we forward your email and URL |
-------------------------------------------------------------