Re: [hylafax-users] [hylafax-users]: How to tell hylafax to skip a job that doesn' t work?



> >Nov 29 16:57:07.65: [16366]: SEND begin page
> >Nov 29 16:57:07.65: [16366]: <-- data [1025]
> >Nov 29 16:57:07.65: [16366]: <-- data [1026]
> >Nov 29 16:57:07.65: [16366]: <-- data [1027]
> >Nov 29 16:57:07.65: [16366]: <-- data [1031]
> >Nov 29 16:57:07.65: [16366]: <-- data [1034]
> >Nov 29 16:57:08.90: [16366]: <-- data [1025]
> >Nov 29 16:58:28.90: [16366]: MODEM WRITE SHORT: sent 1025, wrote 232
> 
> Usually this indicates a driver/firmware problem.  It means that we 
> told the modem to transmit 1025 bytes but the modem only responded with 
> a write-count of 232.

Looks like possible a flow-control error as well...  

Have you tried both software and hardware flow control (ModemFlowControl
in many hylafax-config)