HylaFAX The world's most advanced open source fax server |
Hy
My fax server
is:
PC - Pentium IV Intel 1.7 GHz
1.5 Gbytes RAM Memory
3 x 120 Gbytes Hard disk in Raid 5
Multserial Naxox 8 port RS-232
Linux RedHat 9
Hylafax v 4.1.8-1rh9
10 external modensTrellis model: VM56SV
The problem is many "facsimile
not received" the message with:
An attempt to receive facsimile on ttyS7 failed
because:
---- Transcript of session follows ---- Sep 16 11:18:35.98: [ 1092]: SESSION BEGIN 000162476 5501134432366 Sep 16 11:18:35.98: [ 1092]: HylaFAX (tm) Version 4.1.8 Sep 16 11:18:35.98: [ 1092]: <-- [4:ATA\r] Sep 16 11:18:42.07: [ 1092]: --> [7:CONNECT] Sep 16 11:18:42.07: [ 1092]: ANSWER: FAX CONNECTION DEVICE '/dev/ttyS7' Sep 16 11:18:42.07: [ 1092]: RECV FAX: begin Sep 16 11:18:43.75: [ 1092]: --> [7:CONNECT] Sep 16 11:18:44.28: [ 1092]: --> [2:OK] Sep 16 11:18:44.28: [ 1092]: <-- [9:AT+FRH=3\r] Sep 16 11:18:47.38: [ 1092]: --> [0:] Sep 16 11:18:47.38: [ 1092]: MODEM <Empty line> Sep 16 11:18:47.44: [ 1092]: --> [2:OK] Sep 16 11:18:47.44: [ 1092]: DELAY 1500 ms Sep 16 11:18:48.94: [ 1092]: <-- [9:AT+FTH=3\r] Sep 16 11:18:48.98: [ 1092]: --> [7:CONNECT] Sep 16 11:18:50.77: [ 1092]: --> [7:CONNECT] Sep 16 11:18:51.29: [ 1092]: --> [2:OK] Sep 16 11:18:51.29: [ 1092]: <-- [9:AT+FRH=3\r] Sep 16 11:18:52.13: [ 1092]: --> [7:CONNECT] Sep 16 11:18:53.64: [ 1092]: --> [2:OK] Sep 16 11:18:53.64: [ 1092]: REMOTE TSI "041 264 6708" Sep 16 11:18:53.64: [ 1092]: <-- [9:AT+FRH=3\r] Sep 16 11:18:53.66: [ 1092]: --> [7:CONNECT] Sep 16 11:18:53.98: [ 1092]: --> [2:OK] Sep 16 11:18:53.98: [ 1092]: REMOTE wants 9600 bit/s Sep 16 11:18:53.98: [ 1092]: REMOTE wants page width 1728 pixels in 215 mm Sep 16 11:18:53.98: [ 1092]: REMOTE wants unlimited page length Sep 16 11:18:53.98: [ 1092]: REMOTE wants 3.85 line/mm Sep 16 11:18:53.98: [ 1092]: REMOTE wants 2-D MR Sep 16 11:18:53.98: [ 1092]: RECV training at v.29 9600 bit/s Sep 16 11:18:53.98: [ 1092]: <-- [10:AT+FRM=96\r] Sep 16 11:18:54.61: [ 1092]: --> [7:CONNECT] Sep 16 11:18:56.10: [ 1092]: RECV: TCF 1851 bytes, 2% non-zero, 1801 zero-run Sep 16 11:18:56.10: [ 1092]: --> [10:NO CARRIER] Sep 16 11:18:56.10: [ 1092]: DELAY 75 ms Sep 16 11:18:56.18: [ 1092]: TRAINING succeeded Sep 16 11:18:56.18: [ 1092]: <-- [9:AT+FTH=3\r] Sep 16 11:18:56.22: [ 1092]: --> [7:CONNECT] Sep 16 11:18:57.51: [ 1092]: --> [2:OK] Sep 16 11:18:57.51: [ 1092]: <-- [10:AT+FRM=96\r] Sep 16 11:18:58.21: [ 1092]: --> [7:CONNECT] Sep 16 11:18:58.21: [ 1092]: RECV: begin page Sep 16 11:20:18.87: [ 1092]: RECV: 890 total lines, 0 bad lines, 0 consecutive bad lines Sep 16 11:20:18.87: [ 1092]: RECV: end page Sep 16 11:20:18.87: [ 1092]: --> [10:NO CARRIER] Sep 16 11:20:18.87: [ 1092]: <-- [9:AT+FRH=3\r] Sep 16 11:20:19.24: [ 1092]: --> [7:CONNECT] Sep 16 11:20:20.16: [ 1092]: --> [2:OK] Sep 16 11:20:20.16: [ 1092]: RECV recv EOP (no more pages or documents) Sep 16 11:20:20.16: [ 1092]: <-- [9:AT+FRS=7\r] Sep 16 11:20:20.28: [ 1092]: --> [2:OK] Sep 16 11:20:20.28: [ 1092]: <-- [9:AT+FTH=3\r] Sep 16 11:20:20.32: [ 1092]: --> [7:CONNECT] Sep 16 11:20:21.62: [ 1092]: --> [2:OK] Sep 16 11:20:21.62: [ 1092]: RECV send MCF (message confirmation) Sep 16 11:20:21.62: [ 1092]: RECV FAX (000162476): from 041 264 6708, page 1 in 1:25, INF, 3.85 line/mm, 2-D MR, 9600 bit/s Sep 16 11:20:21.62: [ 1092]: RECV FAX (000162476): recvq/fax000162270.tif from 041 264 6708, route to <unspecified>, 1 pages in 1:39 Sep 16 11:20:21.63: [ 1092]: <-- [9:AT+FRH=3\r] Sep 16 11:20:22.43: [ 1092]: --> [7:CONNECT] Sep 16 11:20:23.41: [ 1092]: --> [2:OK] Sep 16 11:20:23.41: [ 1092]: RECV FAX: bin/faxrcvd "recvq/fax000162270.tif" "ttyS7" "000162476" "" "" "" The
configuration is:
# $Id: class1.0,v 1.1 2002/05/23 21:32:18 darren Exp $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Generic Class 1.0 modem configuration. # # EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP # CountryCode: 55 AreaCode: 11 FAXNumber: "+55.011.3443.2366" LongDistancePrefix: 0 InternationalPrefix: 0 DialStringRules: etc/dialrules ServerTracing: 11 SessionTracing: 11 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 1 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "Buonny Gerenciamento de Riscos Ltda." TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c|Page %%P of %%T" PercentGoodLines: 70 MaxConsecutiveBadLines: 30 MaxRecvPages: 25 # # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # # We use "ModemType: Class1" with "Class1Cmd: AT+FCLASS=1.0" for now # ModemType: Class1 # use this to supply a hint #ModemRate: 19200 # rate for DCE-DTE communication #ModemFlowControl: xonxoff # XON/XOFF flow control assumed # #ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem #ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier #GettyArgs: "-h %l dx_%s" # modem must auto-detect fax/data # # We can append the "@" symbol to the dial string so that # the modem will wait 5 seconds before attempting to connect # and return result codes that distinguish between no carrier # and no answer. This makes it possible to avoid problems with # repeatedly dialing a number that doesn't have a fax machine # (kudos to Stuart Lynne for this trick.) # # NB: If you need to prefix phone numbers to get through a PBX, # put it in the ModemDialCmd; e.g. "DT9%s@". # #ModemDialCmd: ATDT%s # T for tone dialing # # Other possible configuration stuff. The default strings are # shown below. Only those that are different from the defaults # need to be included in the configuration file. # #ModemResetCmds: "" # stuff to do when modem is reset #ModemAnswerCmd: ATA # use this to answer phone #ModemNoFlowCmd: AT&K # disable flow control cmd #ModemHardFlowCmd: AT&K3 # hardware flow control cmd #ModemSoftFlowCmd: AT&K4 # software flow control cmd #ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer # # Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH. # Note that we both turn the speaker on/off and set volume. # #ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1" #ModemEchoOffCmd: ATE0 # disable command echo #ModemVerboseResultsCmd: ATV1 # enable verbose command results #ModemResultCodesCmd: ATQ0 # enable result codes #ModemOnHookCmd: ATH0 # place phone on hook (hangup) #ModemSoftResetCmd: ATZ # do soft reset of modem #ModemSoftResetCmdDelay: 3000 # pause after soft reset #ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier #ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds #ModemRecvFillOrder: LSB2MSB # bit order of received facsimile #ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit # Class1Cmd: AT+FCLASS=1.0 # command to enter class 1.0 Class1PPMWaitCmd: AT+FTS=7 # command to stop and wait before PPM Class1TCFWaitCmd: AT+FTS=7 # command to stop and wait before TCF Class1EOPWaitCmd: AT+FTS=9 # command to stop and wait before EOP Class1TCFResponseDelay: 75 # 75ms delay between recv TCF & response Class1SendMsgDelay: 75 # 75ms delay after training Class1SwitchingDelay: 75 # 150ms delay in switching transmission direction Class1TrainingRecovery: 1500 # 1.5sec delay after training failure Class1RecvAbortOK: 200 # wait 200ms for abort response Class1FrameOverhead: 4 # 4 byte overhead in recvd HDLC frames Class1RecvIdentTimer: 40000 # 35+5secs waiting for ident frames Class1TCFMaxNonZero: 10 # max 10% of data may be non-zero Class1TCFMinRun: 1000 # min run is 2/3rds of TCF duration Do you now how to fix this
problem?
Thank´s
Tecnologia da
Informação João Sergio Caciola Gerente de TI (11) 3443-2535 (11) 2175-2535 ti.gerencia@xxxxxxxxxxxxx -- .:b buonny gerenciamento de riscos ltda.
|