> >Jul 08 12:11:04.11: [ 4235]: <-- [4:ATZ\r] > >Jul 08 12:11:04.25: [ 4235]: --> [2:OK] > >Jul 08 12:11:04.25: [ 4235]: <-- [5:ATE0\r] > >Jul 08 12:11:09.25: [ 4235]: MODEM <Timeout> > > If you issue the above AT commands in cu/minicon, do they work? > > Can you try > ModemATCmdDelay: 100 (200, 300 ... > > just to see if the modem is upset to receive ATE0 too soon after an ATZ? I had similar problems with my Elsa(s) microlink 56k (the timeout does not happen 100% but only maybe 1%-5% and at different AT commands). Giulio, your tip help me! I did some (extreme) testing with a value of 500. Some hundred faxes have been sent until now without the timeout error :-) Lee, the default value is 0, this might bee what you (or Robert?) called "hylafax is demanding". In minicom you probably can not type so fast ;-) Is minicom using a delay here? Harald, does a value of 0 make sense to you? Is something like 10, 20, 50 better? Bernd ____________________ HylaFAX(tm) Users Mailing List _______________________ To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null