At 12:17 PM 5/24/01 -0400, Jay R. Ashworth wrote: >On Thu, May 24, 2001 at 09:03:38AM -0600, Lee Howard wrote: >> At 03:47 AM 5/24/01 -0400, Network wrote: >> >> > below are my settings for HylaFax >> >> > RingsBeforeAnswer: 2 >> >> That RingsBeforeAnswer setting is a problem. CID information is generally >> only passed to the modem on the first RING. Consequently, there is no CID >> information available on the second ring, which is when you're answering, >> and therefore all calls will be rejected unless you've compensated. > >Perhaps I'm missing something... but it's my understanding that the >way modems handle that is that you get > >RING > >NMBR=7275552368 > >RING > >RING > >Since the CNID burst is transmitted after the first ring (to allow >the boxes to sleep), that's when the modem's deliver it, no? Yes. Are we saying something different? Lee. ____________________ HylaFAX(tm) Users Mailing List _______________________ To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null