Re: [hylafax-users] probleme with REMOTE HANGUP:DTE to DCE data underflow (code 43)
At 04:17 PM 1/18/01 +0100, Denis Cartier Millon wrote:
> jan 15 08:00:08.05: [ 2683]: USE 9600 bit/s
> jan 15 08:00:08.05: [ 2683]: USE 1-D MR
> jan 15 08:00:08.05: [ 2683]: <-- [24:AT+FDIS=1,3,0,2,0,0,0,5\r]
> jan 15 08:00:08.16: [ 2683]: --> [2:OK]
> jan 15 08:00:08.16: [ 2683]: <-- [7:AT+FDT\r]
> jan 15 08:00:14.59: [ 2683]: --> [22:+FDCS: 1,3,0,2,0,0,0,5]
> jan 15 08:00:14.59: [ 2683]: --> [7:CONNECT]
> jan 15 08:00:14.59: [ 2683]: SEND wait for XON
> jan 15 08:00:14.59: [ 2683]: --> [1:]
> jan 15 08:00:14.59: [ 2683]: SEND begin page
> jan 15 08:01:43.91: [ 2683]: SENT 81597 bytes of data
> jan 15 08:01:43.91: [ 2683]: SEND end page
> jan 15 08:01:43.91: [ 2683]: --> [9:+FHNG: 43]
> jan 15 08:01:43.91: [ 2683]: REMOTE HANGUP: DTE to DCE data underflow
Yes, DTE to DCE data underflow, obviously. Just look at the time sequence
there.
I don't use Class 2, but I don't see an AT+FLO command being issued here at
all. What is your Class2HFLOCmd set to? Also, was this a freak occurance,
or is this a reproducable error? What version of HylaFAX are you using?