[hylafax-users] Problem with ATS8=2 on olitec/rockwell modem
Dear all,
I am using Hylafax 4.0.2-14 on a debian 2.2 system, and I am experiencing some
troubles with the modem (which is an OLITEC Speed'Com 56000 modem which uses a
Rockwell K56 chipset). The problem occurs in the very begining of the
communication :
Nov 22 18:44:43 ornette FaxGetty[6479]: <-- [15:ATE0V1Q0S0=0H0\r]
Nov 22 18:44:43 ornette FaxGetty[6479]: --> [2:OK]
Nov 22 18:44:43 ornette FaxGetty[6479]: <-- [21:ATS8=2S7=60&K3&D3&C1\r]
Nov 22 18:44:43 ornette FaxGetty[6479]: --> [5:ERROR]
Nov 22 18:44:43 ornette FaxGetty[6479]: MODEM Command error
Experiencing with minicom, I found out that the offending command is indeed
"ATS8=2" which gives an ERROR (the modem doc says that S8 is set to 2 and is
non-modifiable which may be why the problem occurs). The problem is that I
don't see how to modify these initial commands in the config file (must be some
variable that is not present in the default config file).
Any advice ?
Thanks,
_____________________________________________________________________________
Olivier Cappe'
ENST, Dpt. TSI / CNRS URA 820 tel +33 1 45 81 71 11
46 Rue Barrault fax +33 1 45 88 79 35
75634 Paris Cedex 13 mailto:cappe@tsi.enst.fr
France http://www.tsi.enst.fr/~cappe
_____________________________________________________________________________
PS: My config.modem file looks likes :
# $Id: rockwell,v 1.2 1996/06/24 02:58:40 sam Rel $
# ...
# Configuration for a Rockwell-based modem not otherwise handled by
# another prototype configuration file. This file assumes the modem
# is compatible with the Rc144AC, RC96AC or RC144DP.
# ...
ModemType: Class2 # use class 2 interface
ModemRate: 38400
ModemFlowControl: rtscts # default
#
#ModemResetCmds: AT&F2 # what you want for a Supra
ModemNoFlowCmd: AT&K # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
#ModemSetupDTRCmd: AT&D2S25=1S38=0 # Dynalink 1414VE needs this
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FAA=1+FCLASS=0 # enable in current class
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
#
ModemAnswerFaxBeginCmd: "<19200><xon>" # modem switches on fax receive
#
# Caller ID configuration setup for Supra.
#
#QualifyCID: etc/cid # CID access control list file
#CIDNumber: "NMBR = " # pattern string for phone number info
#CIDName: "NAME = " # pattern string for identity info
____________________ HylaFAX(tm) Users Mailing List _______________________
To unsub: mail -s unsubscribe hylafax-users-request@hylafax.org < /dev/null