Re: Trouble receiving Faxes with Elsa Microlink 56k Basic Modem
Karlheinz Blank wrote:
>
> Hi,
>
HI,
try the attached config-file for elsa modem
HIH
/Matthias
> in near future I'll get trouble - cause I'm sitting every night in front of my computer trying to get that following running :-(
>
> - Suse 6.4
> - Hylafax 4.1 beta 2
> - Elsa Microlink 56k basic
>
> I'm running faxaddmodem with defining the modem either as Class 1, 2 or 2.0 type.
> But if I receive a fax, the modem connects - exchanges the FAX-Device-IDs from and to the sending fax-machine - and nothing happens til the sending fax hangs up with an error.
>
> I increased the logging level, I searched through the hylafax archive, I've been changing the modem - nothing helped.
> I was searching the Elsa Homepage but didn't find a config.modem file...
>
> Thanks for any hints.
>
> I've tested the following configs:
>
> CLASS 1:
> -----------
> May 24 23:22:38.36: [ 462]: SESSION BEGIN 00000024 491111111
> May 24 23:22:47.28: [ 462]: ANSWER: FAX CONNECTION
> May 24 23:22:47.28: [ 462]: MODEM input buffering enabled
> May 24 23:22:47.28: [ 462]: RECV FAX: begin
> May 24 23:22:51.15: [ 462]: REMOTE TSI "+491111111"
> May 24 23:22:51.15: [ 462]: REMOTE wants 9600 bit/s
> May 24 23:22:51.15: [ 462]: REMOTE wants page width 1728 pixels in 215 mm
> May 24 23:22:51.15: [ 462]: REMOTE wants unlimited page length
> May 24 23:22:51.15: [ 462]: REMOTE wants 3.85 line/mm
> May 24 23:22:51.15: [ 462]: REMOTE wants 1-D MR
> May 24 23:22:53.76: [ 462]: RECV: begin page
> May 24 23:22:53.76: [ 462]: RECV: send trigger 021
>
> **** Process hangs after that - no more entries in log...
>
> *** SNIP **********
>
> ModemType: Class1 # use this to supply a hint
> ModemRate: 38400 # rate for DCE-DTE communication
> ModemFlowControl: rtscts # XON/XOFF flow control assumed
> # ******** tested with XONXOFF as well.
> GettyArgs: "-h %l dx_%s" # modem must auto-detect fax/data
> Class1Cmd: AT+FCLASS=1 # command to enter class 1
> Class1TCFResponseDelay: 75 # 75ms delay between recv TCF & response
> Class1SendPPMDelay: 75 # 75ms delay before sending PPM
> Class1SendTCFDelay: 75 # 75ms delay between sending DCS & TCF
> Class1TrainingRecovery: 1500 # 1.5sec delay after training failure
> Class1RecvAbortOK: 200 # wait 200ms for abort response
> Class1FrameOverhead: 4 # 4 byte overhead in recvd HDLC frames
> Class1RecvIdentTimer: 40000 # 35+5secs waiting for ident frames
> Class1TCFMaxNonZero: 10 # max 10% of data may be non-zero
> Class1TCFMinRun: 1000 # min run is 2/3rds of TCF duration
>
> *********+ SNIP
>
> Class 2.0
>
> May 24 23:30:11.12: [ 562]: SESSION BEGIN 00000025 49111111
> May 24 23:30:11.12: [ 562]: <-- [4:ATA\r]
> May 24 23:30:17.22: [ 562]: --> [74:+FHT: FF 03 40 20 20 20 48 62 6D 47 20 6B 63 75 72 44 20 6B 69 66 61 72 47]
> May 24 23:30:17.22: [ 562]: --> [26:+FHT: FF 13 80 00 6E F8 00]
> May 24 23:30:19.87: [ 562]: --> [5:+FCON]
> May 24 23:30:21.38: [ 562]: --> [74:+FHR: FF 03 43 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 78 61 46]
> May 24 23:30:21.60: [ 562]: --> [23:+FHR: FF 13 83 00 62 70]
> May 24 23:30:25.03: [ 562]: --> [5:+FCFR]
> May 24 23:30:25.03: [ 562]: --> [28:+FTSI:"Fax "]
> May 24 23:30:25.04: [ 562]: --> [21:+FDCS:1,5,0,0,0,0,0,0]
> May 24 23:30:25.04: [ 562]: --> [2:OK]
> May 24 23:30:25.04: [ 562]: <-- [7:AT+FDR\r]
> May 24 23:30:25.19: [ 562]: --> [14:+FHT: FF 13 84]
> May 24 23:30:27.08: [ 562]: --> [7:CONNECT]
> May 24 23:30:27.08: [ 562]: <-- data [1]
>
> *** Nothing happens after that point.
>
> _______________________________________________________________________
> 1.000.000 DM gewinnen - kostenlos tippen - http://millionenklick.web.de
> IhrName@web.de, 8MB Speicher, Verschluesselung - http://freemail.web.de
--
HAGOS eG phone: +49 711 7880592
Matthias Reich fax: +49 711 7880599
Industriestr. 62 web: http://www.hagos.de
D-70565 Stuttgart mail: rei@hagos.de
Germany
----------------------------------------------------------------------------
Be careful your mail is read by the NSA too !!
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 711
FAXNumber: +49.711.7880549
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 0
SessionTracing: 0
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: off
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "HAGOS eG Stuttgart"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: " Von %%l|%c|Seite %%p von %%t"
QualifyTSI: etc/tsi
MaxRecvPages: 25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use this to supply a hint
ModemRate: 38400
ModemFlowControl: rtscts
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
# We normally append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
ModemDialCmd: ATDT0,%s
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
ModemResetCmds: ATX3 # stuff to do when modem is reset
ModemAnswerCmd: ATA # use this to answer phone
ModemNoFlowCmd: AT\Q0 # disable flow control cmd
ModemHardFlowCmd: AT\Q3 # hardware flow control cmd
ModemSoftFlowCmd: AT\Q1 # software flow control cmd
ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
ModemEchoOffCmd: ATE0 # disable command echo
ModemVerboseResultsCmd: ATV1 # enable verbose command results
ModemResultCodesCmd: ATQ0 # enable result codes
ModemOnHookCmd: ATH
ModemSoftResetCmd: ATZ # do soft reset of modem
ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd: AT+FCLASS=2 # command to enter class 2
Class2BORCmd: AT+FBOR=0 # bit order for phase B/C/D (direct)
Class2RELCmd: AT+FREL=1 # byte-align EOL codes on recv
Class2CQCmd: "" # commands to enable copy quality proc.
Class2AbortCmd: AT+FK # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality capabilities
Class2DCCQueryCmd: AT+FDCC=? # query for modem capabilities
Class2TBCCmd: AT+FTBC=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FPHCTO=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBUG=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLID # set local identifier command
Class2DCCCmd: AT+FDCC # set modem capabilities command
Class2DISCmd: AT+FDIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command hack
Class2CIGCmd: AT+FCIG # set polling identifier command
Class2PTSCmd: AT+FPTS # set post-page status command
Class2SPLCmd: AT+FSPL # set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger: "" # character sent to modem to start recv
Class2XmitWaitForXON: yes # if true, wait for XON before send