Alan Hanson wrote: > > HylaFAX 4.0pl2 version > Solaris 2.7 server > > We have purchased a couple of new Multi-Tech MT3334ZDX modems for > out-going fax. I can not get these modems to send the data out. It > dials up the other modem and immediately disconnects when the called > modem comes online (1/2 sec). The "faxstat -s" indicates that there is > no response from the called fax. > > I have an older Multi-Tech MT2834ZDX modem that worked immediately on > setup. > > In using the "faxaddmodem" routine, I have accepted the default values > and I have attempted to customize the settings and nothing works for me > on these new modems. > > I have attempted to check the settings between the old and new modems > using the AT&V command and all the settings that display are identical. > Not all the setting show up though. How can I see all the settings, for > example all the Sn settings? > > Thanks in advance. > Alan Hanson Hi Alan, did you already try to use the old config-files for your new modems. The only way I know to get the register content is with ATSn=? I attach the config-files, I use for outbound service with MultiTech Modems. I think fort the ZDX Modems you have to change the folling params: (only relevant on outbound service) ModemHardFlowCmd: AT&K3 # hardware flow control cmd ModemSoftFlowCmd: AT&K4 # software flow control cmd ModemSetupAACmd: AT+FAA=1+FCLASS=0 # leave in data class for answer ModemRecvFillOrder: MSB2LSB # opposite of what makes sense Hope it helps Matthias -- HAGOS eG phone: +49 711 7880592 Matthias Reich fax: +49 711 7880599 Industriestr. 62 web: http://www.hagos.de D-70565 Stuttgart mail: rei@hagos.de Germany
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $ # # HylaFAX Facsimile Software # # Copyright (c) 1990-1996 Sam Leffler # Copyright (c) 1991-1996 Silicon Graphics, Inc. # HylaFAX is a trademark of Silicon Graphics, Inc. # # Permission to use, copy, modify, distribute, and sell this software and # its documentation for any purpose is hereby granted without fee, provided # that (i) the above copyright notices and this permission notice appear in # all copies of the software and related documentation, and (ii) the names of # Sam Leffler and Silicon Graphics may not be used in any advertising or # publicity relating to the software without the specific, prior written # permission of Sam Leffler and Silicon Graphics. # # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. # # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE # OF THIS SOFTWARE. # # # Generic Class 2 modem configuration. # # EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP # CountryCode: 49 AreaCode: 711 FAXNumber: +49.711.7880549 LongDistancePrefix: 0 InternationalPrefix: 00 DialStringRules: etc/dialrules ServerTracing: 0x00040 SessionTracing: 11 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 0 SpeakerVolume: high GettyArgs: "-h %l dx_%s" LocalIdentifier: "HAGOS eG Stuttgart" TagLineFont: etc/lutRS18.pcf TagLineFormat: "Von %%l|%c|Seite %%p von %%t" QualifyTSI: etc/tsi PercentGoodLines: 90 MaxConsecutiveBadLines: 10 MaxRecvPages: 25 # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class2 # use class 2 interface ModemRate: 38400 # lock rate for DCE-DTE communication ModemFlowControl: rtscts # default # ModemResetCmds: AT&FX3 ModemHardFlowCmd: AT&E4 # hardware flow control ModemSoftFlowCmd: AT&E5 # software flow control ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2 # # NB: some models get confused by the @ # ModemDialCmd: ATDT0,01030%s # Class2RecvDataTrigger: "\022" # character sent to modem to start recv #