HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
Re: Multi-Tech MT3334ZDX modem question
Alan Hanson wrote:
>
> HylaFAX 4.0pl2 version
> Solaris 2.7 server
>
> We have purchased a couple of new Multi-Tech MT3334ZDX modems for
> out-going fax. I can not get these modems to send the data out. It
> dials up the other modem and immediately disconnects when the called
> modem comes online (1/2 sec). The "faxstat -s" indicates that there is
> no response from the called fax.
>
> I have an older Multi-Tech MT2834ZDX modem that worked immediately on
> setup.
>
> In using the "faxaddmodem" routine, I have accepted the default values
> and I have attempted to customize the settings and nothing works for me
> on these new modems.
>
> I have attempted to check the settings between the old and new modems
> using the AT&V command and all the settings that display are identical.
> Not all the setting show up though. How can I see all the settings, for
> example all the Sn settings?
>
> Thanks in advance.
> Alan Hanson
Hi Alan,
did you already try to use the old config-files for your new modems.
The only way I know to get the register content is with
ATSn=?
I attach the config-files, I use for outbound service with MultiTech
Modems.
I think fort the ZDX Modems you have to change the folling params:
(only relevant on outbound service)
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupAACmd: AT+FAA=1+FCLASS=0 # leave in data class for answer
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
Hope it helps
Matthias
--
HAGOS eG phone: +49 711 7880592
Matthias Reich fax: +49 711 7880599
Industriestr. 62 web: http://www.hagos.de
D-70565 Stuttgart mail: rei@hagos.de
Germany
# $Id: class2,v 1.23 1996/06/24 02:58:32 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
CountryCode: 49
AreaCode: 711
FAXNumber: +49.711.7880549
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 0x00040
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 0
SpeakerVolume: high
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "HAGOS eG Stuttgart"
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "Von %%l|%c|Seite %%p von %%t"
QualifyTSI: etc/tsi
PercentGoodLines: 90
MaxConsecutiveBadLines: 10
MaxRecvPages: 25
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 38400 # lock rate for DCE-DTE communication
ModemFlowControl: rtscts # default
#
ModemResetCmds: AT&FX3
ModemHardFlowCmd: AT&E4 # hardware flow control
ModemSoftFlowCmd: AT&E5 # software flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
ModemSetupAACmd: AT+FAA=1 # enable adaptive-answer in class 2
#
# NB: some models get confused by the @
#
ModemDialCmd: ATDT0,01030%s
#
Class2RecvDataTrigger: "\022" # character sent to modem to start recv
#