HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
Hylafax FDIS error with 33k6 fax machines ?
- To: flexfax@sgi.com
- Subject: flexfax: Hylafax FDIS error with 33k6 fax machines ?
- From: Joost van Vroonhoven <joost@trw.nl>
- Date: Wed, 14 Jul 1999 16:47:09 +0200
Hello,
I use Hylafax 4.0 pl 2 on SunOS 4.1.3U1
with 30 rack mounted MultiTech MT1432BR modems
sending some 6000 pages in some 4000 faxes a day.
On a few of those (some 12) receivers appear not to send the
required FDIS answer, stating their capabilities.
This aborts the transmission.
I get this log file :
Jul 14 16:09:39.06: [23103]: SESSION BEGIN 00007158 31206530032
Jul 14 16:09:39.07: [23103]: SEND FAX: JOB 24019 DEST 0206530032 COMMID
00007158
Jul 14 16:09:39.07: [23103]: DELAY 2600 ms
Jul 14 16:09:41.93: [23103]: <-- [15:ATE0V1Q0S0=0H0\r]
Jul 14 16:09:42.21: [23103]: --> [14:ATE0V1Q0S0=0H0]
Jul 14 16:09:42.21: [23103]: --> [2:OK]
Jul 14 16:09:42.21: [23103]: <-- [21:ATS8=2S7=60&E4&D3&C1\r]
Jul 14 16:09:42.47: [23103]: --> [2:OK]
Jul 14 16:09:42.47: [23103]: <-- [12:AT+FCLASS=2\r]
Jul 14 16:09:42.74: [23103]: --> [2:OK]
Jul 14 16:09:42.74: [23103]: <-- [10:AT+FTBC=0\r]
Jul 14 16:09:43.01: [23103]: --> [2:OK]
Jul 14 16:09:43.01: [23103]: <-- [10:AT+FBOR=0\r]
Jul 14 16:09:43.27: [23103]: --> [2:OK]
Jul 14 16:09:43.27: [23103]: <-- [13:AT+FPHCTO=30\r]
Jul 14 16:09:43.54: [23103]: --> [2:OK]
Jul 14 16:09:43.55: [23103]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
Jul 14 16:09:43.81: [23103]: --> [2:OK]
Jul 14 16:09:43.81: [23103]: <-- [5:ATM0\r]
Jul 14 16:09:44.08: [23103]: --> [2:OK]
Jul 14 16:09:44.11: [23103]: <-- [12:AT+FCLASS=2\r]
Jul 14 16:09:44.47: [23103]: --> [2:OK]
Jul 14 16:09:44.47: [23103]: <-- [10:AT+FTBC=0\r]
Jul 14 16:09:44.83: [23103]: --> [2:OK]
Jul 14 16:09:44.83: [23103]: <-- [10:AT+FBOR=0\r]
Jul 14 16:09:45.17: [23103]: --> [2:OK]
Jul 14 16:09:45.17: [23103]: <-- [13:AT+FPHCTO=30\r]
Jul 14 16:09:45.53: [23103]: --> [2:OK]
Jul 14 16:09:45.53: [23103]: <-- [24:AT+FDCC=1,5,2,2,0,0,0,0\r]
Jul 14 16:09:45.87: [23103]: --> [2:OK]
Jul 14 16:09:45.87: [23103]: <-- [26:AT+FLID="InterpayLeusden"\r]
Jul 14 16:09:46.23: [23103]: --> [2:OK]
Jul 14 16:09:46.23: [23103]: <-- [24:AT+FDIS=0,5,0,2,0,0,0,0\r]
Jul 14 16:09:46.57: [23103]: --> [2:OK]
Jul 14 16:09:46.58: [23103]: DIAL 0206530032
Jul 14 16:09:46.58: [23103]: <-- [16:ATDT0206530032@\r]
Jul 14 16:10:02.06: [23103]: --> [5:+FCON]
Jul 14 16:10:04.89: [23103]: --> [117:+FNSF:00 00 21 01 0D 02 25 58 02
9F 3C 10 20 20 32 33 30 30 33 35 36 20 30 32 20 31 33 2B 01 04 01 0A 01
08 02 60 0B ]
Jul 14 16:10:04.89: [23103]: REMOTE NSF "00 00 21 01 0D 02 25 58 02 9F
3C 10 20 20 32 33 30 30 33 35 36 20 30 32 20 31 33 2B 01 04 01 0A 01 08
02 60 0B"
Jul 14 16:10:04.89: [23103]: --> [28:+FCSI:" +31 20 6530032"]
Jul 14 16:10:04.89: [23103]: REMOTE CSI "+31 20 6530032"
Jul 14 16:10:04.89: [23103]: --> [6:+FDIS:]
Jul 14 16:10:04.89: [23103]: MODEM protocol botch, can not parse ""
Jul 14 16:10:04.89: [23103]: --> [2:OK]
Jul 14 16:10:04.89: [23103]: REMOTE HANGUP: Unspecified Transmit Phase B
error (code 20)
Jul 14 16:10:04.90: [23103]: SEND FAILED: Unspecified Transmit Phase B
error
Jul 14 16:10:04.90: [23103]: <-- [5:ATH0\r]
Jul 14 16:10:06.54: [23103]: --> [7:+FHNG:2]
Jul 14 16:10:06.54: [23103]: REMOTE HANGUP: Call aborted, from +FK or
<CAN> (code 2)
Jul 14 16:10:07.11: [23103]: --> [2:OK]
Jul 14 16:10:07.27: [23103]: SESSION END
The message I see in all failed logs is the same :
Jul 14 16:10:04.89: [23103]: --> [6:+FDIS:]
Jul 14 16:10:04.89: [23103]: MODEM protocol botch, can not parse ""
This happens with a number of different receiving fax machines,
all of whom appear to support 33k6 reception (aka. SuperG3).
I have communicated with Minolta who tried disabling ECM on their
receiving machine, still no joy.
Then we tried again after disabling high speed reception (i.e.. 33k6 /
28k8)
and that fixed / circumvented the problem.
This same 'fix' worked on a Canon L900.
With a tech person at OKI we tried their 5500, 5700 and 4500 with the
following result :
5500 with ECM failed
5500 no ECM success
5700 with ECM failed
5700 no ECM success
4500 with ECM success
So it seems disabling 33k6 reception of faxes on the receiving end
avoids the problem.
And disabling ECM on 33k6 OKI machines avoids it too.
My question : what can I change in the HylaFax setup to never see this
problem,
even with 33k6 fax machines ?
Thanks for your time,
Joost
--
| joost@trw.nl , J.W.J. van Vroonhoven | \ / |
| Senior Software Support Engineer | _____-/\-_____ \ / |
| TRW Data Services Europe | \_\/_/ _____-/\-_____ |
| BGC site, Leusden, Holland | \_\/_/ |
| work: +31 205631951 fax: +31 334945718 | |
| home: +31 334325995 cel: +31 653142109 | Lockheed F-22A Raptor |