Hi Ulrich, At 11:27 AM 12/3/98 +0100, Ulrich Eckhardt wrote: >Hi, > >this patch helped against the RTN problem :-) but the good old >REMOTE HANGUP: No response to EOP repeated 3 times (code 54) >is also present. Excellent - thats the combination of both the tagline & speed reduce patches. Re the EOP problem, does that happen consistently to certain locations, or is it random, does it still occur with a different modem or the modem running in class1? >Is there some good documentation about the fax protocol availabe >somewhere ? There's a little bit of information here: http://www.hylafax.org/Modems/Supra/class2.php and http://www.hylafax.org/Modems/Supra/class1.php You can order the fax-standard documents, they take around 8 weeks to arrive at least in Oz. It is much quicker to download them from http://www.itu.int/ you will need a credit card though. - Robert