![]() |
> > Hello - I've seen this error in the archives quite a few times and tried a It's a symptom, not an error, and it is the most likely failure mode of any once the modems are talking. It simply means that the initial, 300bps, parameter negotiation went badly wrong. > few of the solutions offered with no success. I am using NetBSD 1.3.2/i386 > and Hylafax 4.0 pl 2, with a Cardinal Connecta 56K D/F Model 3440. Interesting, because you have classic Sportster symptoms. I didn't think that USR went in for badge engineering. > Sep 14 17:03:27.42: [ 1435]: --> [4:+FCO] > Sep 14 17:03:30.54: [ 1435]: --> [39:+FNF:ESC+FCI:" > 6138372938"^T+FIS:] ^ classic Sportster symptom. > Sep 14 17:03:30.54: [ 1435]: REMOTE NSF "ESC+FCI:" > 6138372938"^T+FIS:"