HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: Got disconnected before SEND FILE



> Aug 20 16:25:57.24: [  824]: USE 20 ms, 10 ms/scanline
> Aug 20 16:25:57.24: [  824]: <-- [5:ATH0\r]
> Aug 20 16:25:58.86: [  824]: --> [7:+FHNG:2]
> Aug 20 16:25:58.86: [  824]: REMOTE HANGUP: Call aborted,  from +FK or
> <CAN> (co
> de 2)

Hylafax aborted the call during phase B (option negotiation).  The legitimate
reason for this would be that the last time it called the number the remote
machine was prepared to accept a more efficient fax coding (possibly because
it is a modem pool and you got a different modem), an Hylafax has code that
way be now needs to regenerate the fax data.  If this is the case
(and the fax will go eventually in that case), use & to lock down the lower
specification in the info file.




Project hosted by iFAX Solutions