I have hylafax-v4.0pl2 built on a RedHat-5 linux system, using std compiler and libraries (gcc-2.7.2.3 & glibc-2.0.5?) When I attempt to send a fax, I get an error "modem problem". What interests me in the following log file is that hylafax seems to give up just before the modem acheives a connect. Is this some kind of timing problem (16550A maybe - I've tried turning the FIFO off - don't know if I succeeded) Am I looking in the wrong place ? ===== Log file ===== Apr 19 16:02:18.61: [11891]: SESSION BEGIN 00000037 61894304494 Apr 19 16:02:18.61: [11891]: SEND FAX: JOB 12 DEST 94304494 COMMID 00000037 Apr 19 16:02:18.61: [11891]: DELAY 2600 ms Apr 19 16:02:21.22: [11891]: <-- [15:ATE0V1Q0S0=0H0\r] Apr 19 16:02:26.22: [11891]: MODEM <Timeout> Apr 19 16:02:26.22: [11891]: <-- [5:ATM0\r] Apr 19 16:02:26.48: [11891]: --> [4:ATM0] Apr 19 16:02:26.49: [11891]: --> [2:OK] Apr 19 16:02:26.51: [11891]: <-- [12:AT+FCLASS=1\r] Apr 19 16:02:26.89: [11891]: --> [11:AT+FCLASS=1] Apr 19 16:02:26.89: [11891]: --> [2:OK] Apr 19 16:02:26.91: [11891]: DIAL 94304494 Apr 19 16:02:26.91: [11891]: <-- [13:ATDT94304494\r] Apr 19 16:02:39.26: [11891]: --> [12:ATDT94304494] Apr 19 16:02:39.26: [11891]: SEND FAILED: Unknown problem (check modem power) Apr 19 16:02:39.26: [11891]: <-- [5:ATH0\r] Apr 19 16:02:39.26: [11891]: --> [7:CONNECT] Apr 19 16:02:39.52: [11891]: --> [2:OK] Apr 19 16:02:39.52: [11891]: SESSION END ===== config.cua1 ===== # # Configuration for a Rockwell-based Class 1 modem. # SupraFAX v.32bis firmware V1.200-C or newer # (and others) # # This configuration file sets up the modem to run at 38.4 # and use RTS/CTS flow control by default. # # CountryCode: 61 AreaCode: 8 FAXNumber: "9430 4494" LongDistancePrefix: 0 InternationalPrefix: 0011 DialStringRules: etc/dialrules ServerTracing: 1 SessionTracing: 11 RecvFileMode: 0600 LogFileMode: 0600 DeviceMode: 0600 RingsBeforeAnswer: 3 SpeakerVolume: off GettyArgs: "-h %l dx_%s" LocalIdentifier: "NothingSetup" ClocalAsRoot: yes TagLineFont: etc/lutRS18.pcf TagLineFormat: "From %%l|%c|Page %%p of %%t" MaxRecvPages: 25 # # # Modem-related stuff: should reflect modem command interface # and hardware connection/cabling (e.g. flow control). # ModemType: Class1 # use class 1 interface ModemRate: 38400 ModemFlowControl: rtscts # default # ModemNoFlowCmd: AT&K # disable flow control cmd ModemHardFlowCmd: AT&K3 # hardware flow control cmd ModemSoftFlowCmd: AT&K4 # software flow control cmd ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not) ModemSetupAACmd: AT+FAA=0 # in case modem supports Class 2 also # ModemMfrQueryCmd: !Rockwell # no way to query modem ModemModelQueryCmd: !RC32ACL # not always right ModemRevQueryCmd: ATI3