![]() |
-----BEGIN PGP SIGNED MESSAGE----- On Fri, 6 Feb 1998, Raj Mathur wrote: > Date: Fri, 6 Feb 1998 12:16:59 +0530 > From: Raj Mathur <raju@sgi.com> > To: flexfax@sgi.com > Subject: flexfax: Remote machine hangs up on MPS > > hylafax-v4.0pl1 on an SGI O2 IRIX 6.3 GCC 2.6.3 > > Motorola UDS Fastalk II > > Sendfax sends the first page of the fax fine, but the connection > closes once the server sends the MPS (more pages same document) > command. Hmm. Multiple documents? Are all parts of your fax in the same resolution (which might help, if there is some screwballness going on there)? > Feb 06 12:05:40.25: [ 2317]: MODEM set DTR OFF > Feb 06 12:05:40.25: [ 2317]: MODEM set baud rate: 0 baud (flow control unchanged) > Feb 06 12:05:40.25: [ 2317]: DELAY 2600 ms > Feb 06 12:05:42.85: [ 2317]: MODEM set DTR ON > Feb 06 12:05:42.85: [ 2317]: MODEM set baud rate: 38400 baud, input flow RTS/CTS, output flow RTS/CTS I also seem to remember a problem with RTS/CTS under some IRIX operating systems. Have you tried software flow control? > Feb 06 12:05:43.94: [ 2317]: <-- [12:AT+FCLASS=2\r] > Feb 06 12:05:44.05: [ 2317]: --> [2:OK] > Feb 06 12:05:44.05: [ 2317]: <-- [10:AT+FTBC=0\r] > Feb 06 12:05:44.16: [ 2317]: --> [5:ERROR] > Feb 06 12:05:44.16: [ 2317]: MODEM Command error Whoops! You might also try using Class 1: a lot of modems seem to have problems in Class 2 or 2.0, and I haven't seen any simple fix posted. Also, why is it barfing on this command? You might run probemodem to check on this, and look in the manuals. > Feb 06 12:05:44.16: [ 2317]: <-- [10:AT+FBOR=0\r] > Feb 06 12:05:44.26: [ 2317]: --> [2:OK] > Feb 06 12:05:44.26: [ 2317]: <-- [13:AT+FPHCTO=30\r] > Feb 06 12:05:44.37: [ 2317]: --> [5:ERROR] > Feb 06 12:05:44.37: [ 2317]: MODEM Command error Yup, barfing again. > Feb 06 12:06:25.39: [ 2317]: <-- data [2] > Feb 06 12:06:25.39: [ 2317]: SEND end page > Feb 06 12:06:34.64: [ 2317]: --> [54:^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q^S^Q] > Feb 06 12:06:34.64: [ 2317]: --> [2:OK] Umm. Flow control barfage? > Feb 06 12:06:34.64: [ 2317]: SEND send MPS (more pages, same document) > Feb 06 12:06:34.64: [ 2317]: <-- [9:AT+FET=0\r] > Feb 06 12:06:42.85: [ 2317]: --> [9:+FHNG: 53] > Feb 06 12:06:42.85: [ 2317]: REMOTE HANGUP: Invalid response to MPS (code 53) > Feb 06 12:06:42.85: [ 2317]: <-- [5:ATH0\r] > Feb 06 12:06:42.85: [ 2317]: --> [2:OK] > Feb 06 12:06:42.85: [ 2317]: MODEM set DTR OFF > Feb 06 12:06:42.85: [ 2317]: MODEM set baud rate: 0 baud (flow control unchanged) > Feb 06 12:06:42.87: [ 2317]: STATE CHANGE: SENDING -> MODEMWAIT (timeout 5) > Feb 06 12:06:42.87: [ 2317]: SESSION END And it's finally dead..... Try Class 1 and see what happens? Nico Garcia Engineer, CIRL Mass. Eye and Ear Infirmary raoul@cirl.meei.harvard.edu -----BEGIN PGP SIGNATURE----- Version: 2.6.2 iQCVAwUBNNs9jz/+ItycgIJRAQFL1QP7BCRCaaAoURl9fUyOnmES8LmWe8+07uLV tdPnSdpHv5Kyjm4zllACmXg2RRWPkfSJ7oi3gpOp9VYgA6SyMeIULlo3cpaU6geC M22z/e5s2laIjAwyZ3efGEXi+IhPe9SCBTqR3p1CCFS+iBLyNhHEvF/s87rK9W+Q bwKJKTo2d6c= =LLOd -----END PGP SIGNATURE-----