On Fri, 17 Oct 1997, Thomas Unger wrote: > Hi again. I'm running HylaFax 4.0 on freebsd with a ZOOM K56. > > I've hooked up this modem and have started working with getting it to > work. In hand tests it seems to do adaptive answer BUT for data mode > I need to have the following occur: > > 1) modem says "RING" > 2) send command "ATA" > 3) modem says "DATA" > 4) send command "ATO" > 5) modem says "CONNECT xxxx" Try idling in class 0 (ie data) mode instead, and this may eliminate the manual switching with ATO that appears that you're having to do. At a guess, you could possibly enable this with ModemSetupAACmd: AT+FAA=1;AT+FCLASS=0 or ModemSetupAACmd: AT+FAA=1+FCLASS=0 (some modems hate the `;') -- Jonathan Chen e-mail : jonc@pinnacle.co.nz Pinnacle Software Ltd Voice : +64.9.415.4460 Auckland, New Zealand Fax : +64.9.415.4250