USR Sport 33.6
Hi,
we are using hylafax 4.0pl1 on IRIX 6.2. We use US Robotics Sport 33.6
It's connected to ttym2 (the file /var/spool/fax/etc/config.ttym2 is
attached).
I've troble when sending fax. The outgoing fax is OK, notify OK,
but "I don't know who" do not restart /usr/local/sbin/faxgetty ttym2
so the faxmodem do not detected TR and are not able to receive fax.
when I kill faxgetty it's "respawn" and everything looks OK.
line in inittab:
t2:23:respawn:/usr/local/sbin/faxgetty ttym2
the file /var/spool/fax/etc/config.ttym2 (we us it as Class 1 modem):
CountryCode: 42
AreaCode: 5
FAXNumber: +42.5.41245982
LongDistancePrefix: 0
InternationalPrefix: 00
DialStringRules: etc/dialrules
ServerTracing: 1
SessionTracing: 11
RecvFileMode: 0600
LogFileMode: 0600
DeviceMode: 0600
RingsBeforeAnswer: 1
SpeakerVolume: low
GettyArgs: "-h %l dx_%s"
LocalIdentifier: "SkyNet, s.r.o."
TagLineFont: etc/lutRS18.pcf
TagLineFormat: "From %%l|%c|Page %%p of %%t"
#QualifyTSI: etc/tsi
MaxRecvPages: 25
ModemType: Class1 # use class 1 interface
ModemRate: 38400 # DCE-DTE communication rate
ModemFlowControl: xonxoff # XON/XOFF flow control assumed
#
ModemNoFlowCmd: AT&H0&I0&R1 # setup modem for no flow
control
ModemHardFlowCmd: AT&H1&I0&R2 # setup modem for hardware flow
control
ModemSoftFlowCmd: AT&H2&I2&R1 # setup modem for software flow
control
#
ModemSetupDTRCmd: ATS13=1&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier
(or not)ModemResultCodesCmd: ATQ0X3 # enable extended result
codes
#ModemDialCmd: ATDP%s@
ModemDialCmd: ATDP%s
Class1Cmd: AT+FCLASS=1 # command to enter class 1
Class1TCFResponseDelay: 75 # 75ms delay between recv TCF &
responseClass1SendPPMDelay: 75 # 75ms delay before
sending PPM
Class1SendTCFDelay: 75 # 75ms delay between sending DCS
& TCF
Class1TrainingRecovery: 1500 # 1.5sec delay after training
failure
Class1RecvAbortOK: 200 # wait 200ms for abort response
Class1FrameOverhead: 4 # 4 byte overhead in recvd HDLC
frames
Class1RecvIdentTimer: 40000 # 35+5secs waiting for ident
frames
Class1TCFMaxNonZero: 10 # max 10% of data may be
non-zero
Class1TCFMinRun: 1000
Thank you very much for help........
Roman Pavlik e-mail:Roman.Pavlik@www.cz
http://www.cz
SkyNet, s.r.o.
Kabatnikova 5 tel: +42 5 41 24 59 79
602 00 Brno fax: +42 5 41 24 59 82
Czech Republic