HylaFAX The world's most advanced open source fax server

[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index] [Thread Index]

Re: [hylafax-users] Eicon board modem speeds



Dominique,

According to a previous post, you turned off the Class 2 V34 speed indicator explicitly in the dialogic config. As a result, you've told the diva board to lie to HylaFAX even more than usual. I'm confident you'll find that your Dialogic board is sending at speeds higher than 14,400, it's just not telling HylaFAX about it as you have requested.

Incidentally, this board is being discontinued by Dialogic at the end of the year .... if you're using their support a lot I would recommend  you I would try to work out as many of the kinks before that time!

-Darren

On Dec 3, 2008, at 2:30 AM, Dominique dHotman wrote:

Greetings,

My question is about modem speeds with the Eicon fax board.

Our configuration:

hylafax-4.4.4-1rhel5 binary install
RedHat EL5
Kernel 2.6.18-92.el5
Eicon 30 channel diva server board

The modem configuration:

# $Id: eicon-2,v 1.2 2004/03/05 02:29:32 lhoward Exp $
#
# prototype config file for the Eicon Diva ISDN Modem
#

#
#
CountryCode:            27
AreaCode:               21
FAXNumber:              +27.21.XXX.XXXX
LongDistancePrefix:     0
InternationalPrefix:    00
DialStringRules:        "etc/dialrules"
ServerTracing:          0xfff
SessionTracing:         0xfff
RecvFileMode:           0650
LogFileMode:            0650
DeviceMode:             0600
RingsBeforeAnswer:      2
SpeakerVolume:          off
GettyArgs:              "-b -r -s %s %l"
LocalIdentifier:        "ooba(pty)ltd HylaFax"
TagLineFont:            etc/lutRS18.pcf
TagLineFormat:          "From %%l|%c|Page %%P of %%T"
QualifyCID:             etc/cid
MaxRecvPages:           500
#
#

ModemType:              Class2
ModemRate:              57600   # on boards supporting V.34-fax,
                                # this may need to be 57600
ModemFlowControl:       rtscts
ModemNoFlowCmd:         AT&K0
ModemSoftFlowCmd:       AT&K4
ModemHardFlowCmd:       AT&K3

Class2APQueryCmd:       none
Class2SPLCmd:           none
Class2TBCCmd:           none
Class2ECMType:          2.0     # follows Class 2.0 spec, not Class 2

#Bind Modem to Controller 1
ModemResetCmds:         AT#CID=14+iQ=a1
# Put the Destination Address in CIDNumber. We can the reject calls on the basis
# Of where we are sending them, instead of the Caller ID
CIDNumber:              "DAD: "
CIDName:                "CID: "
QualifyCID:             etc/cid         # CID access control list file

Using the testfax utility that is installed with the Dialogic drivers we are able to send and receive fax at speeds of 33600 but when using HylaFAX the max send speed we have been able to achieve is 14400.

Looking through the comm logs the best HylaFAX ever offers is 14400.

Any help would be greatly appreciated as resolving this problem would significantly reduce our fax costs.

Thanks
Dominique