Re: [hylafax-users] weird transmission error
Matthias Reich wrote:
using the the Multitech MT 1432-BG modems.
failure is:
Okt 12 11:27:01.23: [ 4333]: <-- [9:AT+FET=2\r]
Okt 12 11:27:04.46: [ 4333]: --> [14:+FHT:FF 13 2F ]
Okt 12 11:27:05.96: [ 4333]: --> [14:+FHT:FF 13 2F ]
Okt 12 11:27:07.45: [ 4333]: --> [14:+FHT:FF 13 2F ]
Okt 12 11:27:08.95: [ 4333]: --> [14:+FHT:FF 13 FB ]
Okt 12 11:27:09.42: [ 4333]: --> [8:+FHNG:54]
You've come into a fax protocol error (no response to EOP repeated 3
times) with a Class 2 modem that is no longer supported by the
manufacturer. I think that your options at this point are to find some
"workaround" of sorts (try using 1-D MH, for example), to live with it,
or to replace the modems. (Unless the modems support Class 1 and you
can switch to it.)
Lee.