Re: [hylafax-users] MT5634ZPX-PCI-U. What class do you set it up as?
From: "Kenn Vryenhoek" <lists@xxxxxxx>
Hi There,
I'm playing with Hylafax and have it set up to send and receive.
Sending is pretty reliable, about 99% successful and it is great.
Receiving on the other hand is less than 50%.
I've set my MULTI-TECH SYSTEMS MT5634ZPX-PCI-U up as Class 2.1 but have
read in other places that it should be setup as a Class 1.
What have other users of this modem set it up as?
Thanks for your input,
Kenn
HylaFax 4.2.1-4 under Suse 9.3 with gcc 3.3.5-5 and libtiff 3.7.1-7;
MODEM MULTI-TECH SYSTEMS MT5634ZPX-PCI-U with Rev 1.32i firmware
Hi Kenn,
I have two of these same modems. I recommend running them as class 1.0 to
take advantage of the SuperG3 higher speeds.
I've found them to be very reliable.
HTH,
Mike