HylaFAX The world's
most advanced open source fax server
|
|
[
Date Prev][
Date Next][
Thread Prev][
Thread Next]
[
Date Index]
[
Thread Index]
[hylafax-users]
we traying to use HylaFax with a ZyXEL U-90E Modem
I have twi different log file usen Class 2.0 and 1
Mar 13 13:39:49.69: [ 5640]: SESSION BEGIN 000000155 0045702
Mar 13 13:39:49.69: [ 5640]: HylaFAX (tm) Version 4.2.1
Mar 13 13:39:49.69: [ 5640]: <-- [4:ATA\r]
Mar 13 13:40:33.93: [ 5640]: --> [7:+FHS:70]
Mar 13 13:40:33.93: [ 5640]: REMOTE HANGUP: Unspecified Receive Phase B
error (code 70)
Mar 13 13:40:33.93: [ 5640]: ANSWER: Ring detected without successful
handshake
Mar 13 13:40:33.93: [ 5640]: SESSION END
Mar 13 14:26:17.35: [ 8553]: SESSION BEGIN 000000167 0045702
Mar 13 14:26:17.35: [ 8553]: HylaFAX (tm) Version 4.2.1
Mar 13 14:26:17.35: [ 8553]: <-- [4:ATA\r]
Mar 13 14:26:28.03: [ 8553]: --> [3:FAX]
Mar 13 14:26:28.03: [ 8553]: ANSWER: FAX CONNECTION DEVICE '/dev/ttyS0'
Mar 13 14:26:28.03: [ 8553]: RECV FAX: begin
Mar 13 14:26:28.06: [ 8553]: <-- data [32]
Mar 13 14:26:28.06: [ 8553]: <-- data [2]
Mar 13 14:26:29.04: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:29.04: [ 8553]: <-- data [23]
Mar 13 14:26:29.04: [ 8553]: <-- data [2]
Mar 13 14:26:30.26: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:30.26: [ 8553]: <-- data [10]
Mar 13 14:26:30.26: [ 8553]: <-- data [2]
Mar 13 14:26:31.26: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:31.67: [ 8553]: --> [2:OK]
Mar 13 14:26:31.67: [ 8553]: <-- [9:AT+FRH=3\r]
Mar 13 14:26:34.77: [ 8553]: --> [0:]
Mar 13 14:26:34.77: [ 8553]: MODEM <Empty line>
Mar 13 14:26:34.77: [ 8553]: <-- data [1]
Mar 13 14:26:34.78: [ 8553]: --> [2:OK]
Mar 13 14:26:34.78: [ 8553]: DELAY 1500 ms
Mar 13 14:26:36.28: [ 8553]: <-- [9:AT+FTH=3\r]
Mar 13 14:26:37.32: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:37.32: [ 8553]: <-- data [32]
Mar 13 14:26:37.32: [ 8553]: <-- data [2]
Mar 13 14:26:38.58: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:38.58: [ 8553]: <-- data [23]
Mar 13 14:26:38.58: [ 8553]: <-- data [2]
Mar 13 14:26:39.61: [ 8553]: --> [7:CONNECT]
Mar 13 14:26:39.61: [ 8553]: <-- data [10]
Mar 13 14:26:39.61: [ 8553]: <-- data [2]
Mar 13 14:26:40.04: [ 8553]: --> [2:OK]
Mar 13 14:26:40.04: [ 8553]: <-- [9:AT+FRH=3\r]
Mar 13 14:26:43.14: [ 8553]: --> [0:]
Mar 13 14:26:43.14: [ 8553]: MODEM <Empty line>
what fax class should we use ?? and why can't we make it work
either vwith class 1 or 2 ?