Re: [hylafax-users] EICON DIVA 4 BRI and Hylafax



On Thursday 04 November 2004 14:00, Guido Boeri wrote:

> As you can see there is  SESSION BEGIN but this session is never
> closed..... I'm getting mad trying to understand why....

I noticed something interesting yesterday... when I invoke 'c2faxsend' 
manually and left it running, I happened to execute 'ls' later on and found 
that the 'divacapi' module had a 'use count' of 28 which corresponded roughly 
to the number of 'Connection established' blocks on-screen ... could you try 
the same sort of thing?

It would seem this might be a bug in c2faxsend where it is not releasing the 
capi device properly.

I'm using kernel 2.6.8.1, with all the modules that come with that kernel - 
I'm not using any rpms/ sources from Eicon except for the firmware files 
themselves.