On 2003.09.23 09:44 Andrea Nicolini wrote:

Sep 23 16:01:36.44: [15171]: <-- [10:AT+FRM=96\r]
Sep 23 16:01:37.75: [15171]: --> [7:CONNECT]
Sep 23 16:01:37.75: [15171]: RECV: begin page
Sep 23 16:02:05.06: [15171]: RECV: 0 total lines, 0 bad lines, 0
consecutive bad lines
Sep 23 16:02:05.06: [15171]: RECV: end page
Sep 23 16:02:05.06: [15171]: --> [10:NO CARRIER]

Well, the problem is that the modem appears to have received absolutely no TIFF data during phase C, thus "0 total lines".


You could verify this by putting "TracingMask: 0x11" before SessionTracing in your config file, restart faxgetty, and try the fax again. It almost looks as if the remote system just kept the carrier up for ~30 seconds without sending anything.

Lee.